Individual parts - Octavia(OCT) [EUROPA 2005 year]

Individual parts  - Octavia - oct
â„– part number information description remark unit model
Wiring set for electronicallyregulated air-conditioning
Wiring set for electronicallyregulated air-conditioning
Wiring set for electronicallyregulated air-conditioning F >> 1U-12498 634 F >> 1U-18453 264
Wiring set for electronicallyregulated air-conditioning F >> 1U-12498 634 F >> 1U-18453 264
(1)   1J1 971 566 N    1J1 971 566 N qty: 1
Wiring set for electronicallyregulated air-conditioning
  Wiring set for electronicallyregulated air-conditioning lhd 1
(1)   1J1 971 566 P    1J1 971 566 P qty: 1
Wiring set for electronicallyregulated air-conditioningmapped cooling
  Wiring set for electronicallyregulated air-conditioningmapped cooling lhd 1
(1)   1J2 971 566 N    1J2 971 566 N qty: 1
Wiring set for electronicallyregulated air-conditioning
  Wiring set for electronicallyregulated air-conditioning rhd 1
(1)   1J2 971 566 P    1J2 971 566 P qty: 1
Wiring set for electronicallyregulated air-conditioningmapped cooling
  Wiring set for electronicallyregulated air-conditioningmapped cooling rhd 1
Wiring set for electronicallyregulated air-conditioning F 1U-12498 635>> 1U-42840 086 F 1U-18453 265>> 1U-48724 053
Wiring set for electronicallyregulated air-conditioning F 1U-12498 635>> 1U-42840 086 F 1U-18453 265>> 1U-48724 053
(1)   1J1 971 566 A K   1J1 971 566 A K qty: 1
Wiring set for electronicallyregulated air-conditioning
  Wiring set for electronicallyregulated air-conditioning lhd 1
(1)   1J1 971 566 A N   1J1 971 566 A N qty: 1
Wiring set for electronicallyregulated air-conditioningmapped cooling
  Wiring set for electronicallyregulated air-conditioningmapped cooling lhd 1
(1)   1J2 971 566 A K   1J2 971 566 A K qty: 1
Wiring set for electronicallyregulated air-conditioning
  Wiring set for electronicallyregulated air-conditioning rhd 1
(1)   1J2 971 566 A N   1J2 971 566 A N qty: 1
Wiring set for electronicallyregulated air-conditioningmapped cooling
  Wiring set for electronicallyregulated air-conditioningmapped cooling rhd 1
Wiring set for electronicallyregulated air-conditioning F 1U-12498 635>> F 1U-18453 265>> F 1U-7B006 167>>
Wiring set for electronicallyregulated air-conditioning F 1U-12498 635>> F 1U-18453 265>> F 1U-7B006 167>>
(1)   1J1 971 566 B C   1J1 971 566 B C qty: 1
Wiring set for electronicallyregulated air-conditioning
  Wiring set for electronicallyregulated air-conditioning lhd 1
(1)   1J1 971 566 B D   1J1 971 566 B D qty: 1
Wiring set for electronicallyregulated air-conditioningmapped cooling
  Wiring set for electronicallyregulated air-conditioningmapped cooling lhd 1
(1)   1J2 971 566 A P   1J2 971 566 A P qty: 1
Wiring set for electronicallyregulated air-conditioning
  Wiring set for electronicallyregulated air-conditioning rhd 1
(1)   1J2 971 566 A Q   1J2 971 566 A Q qty: 1
Wiring set for electronicallyregulated air-conditioningmapped cooling
  Wiring set for electronicallyregulated air-conditioningmapped cooling rhd 1
Individual parts
Individual parts
3   1J0 959 971    1J0 959 971 qty: 1
Flat contact housingConnection pieceFan Possible single wire:
  Flat contact housingConnection pieceFan Possible single wire: 2 pin
000 979 227 E
1
(3B)   8L0 971 838    8L0 971 838 qty: X
Cable tie with holder for plastic pin:
  Cable tie with holder for plastic pin: 5X200 5 X
(3B)   1J5 971 003    1J5 971 003 qty: X
BracketConnection piecea-pillar
  BracketConnection piecea-pillar X
(4)   1J0 971 972    1J0 971 972 qty: || || || || || || 1
flat connector housingConnection pieceTemperature sensorEvaporator housing Possible single wire: F 1U-12498 638>>
F 1U-18453 264>>
F 1U-7B006 167>>

  flat connector housingConnection pieceTemperature sensorEvaporator housing Possible single wire: F 1U-12498 638>>
F 1U-18453 264>>
F 1U-7B006 167>>
2 pin
000 979 131 E 000 979 131 EA
|| || || || || || 1
4   1J0 972 923    1J0 972 923 qty: 1
Flat contact housing withcontact locking mechanismConnection pieceTemperature sensorIntake air duct Possible single wire:
  Flat contact housing withcontact locking mechanismConnection pieceTemperature sensorIntake air duct Possible single wire: 2 pin
000 979 133 000 979 133 EA
1
(4A)   3B0 972 702    3B0 972 702 qty: 1
Flat contact housing withcontact locking mechanismConnection pieceTemperature sensorFootwell vent Possible single wire:
  Flat contact housing withcontact locking mechanismConnection pieceTemperature sensorFootwell vent Possible single wire: 2 pin
000 979 131 E 000 979 131 EA
1
5   535 972 705    535 972 705 qty: 1
Flat contact housingConnection pieceventilation flap Possible single wire:
  Flat contact housingConnection pieceventilation flap Possible single wire: 5 pin
000 979 131 E 000 979 131 EA
1
6   6Q0 972 736    6Q0 972 736 qty: 1
Flat contact housing withcontact locking mechanismCoupling elementwiring harness for interior Possible single wire:
  Flat contact housing withcontact locking mechanismCoupling elementwiring harness for interior Possible single wire: 12 pin
000 979 132 E 000 979 132 EA
1
(6)   6Q0 972 777    6Q0 972 777 qty: 1
Flat contact housing withcontact locking mechanismCoupling elementwiring harness for interior Possible single wire:
  Flat contact housing withcontact locking mechanismCoupling elementwiring harness for interior Possible single wire: 17-pin
000 979 132 E 000 979 228 E
1
7   1J0 959 971    1J0 959 971 qty: 1
Flat contact housingConnection pieceFan motor Possible single wire:
  Flat contact housingConnection pieceFan motor Possible single wire: 2 pin
000 979 227 E
1
(7)   1J0 972 923    1J0 972 923 qty: 1
Flat contact housing withcontact locking mechanismConnection pieceTemperature sensor Possible single wire:
  Flat contact housing withcontact locking mechanismConnection pieceTemperature sensor Possible single wire: 2 pin
000 979 133 000 979 133 EA
1
(8)   1J0 972 753    1J0 972 753 qty: 1
Flat contact housingConnection pieceFan control Possible single wire:
  Flat contact housingConnection pieceFan control Possible single wire: 3 pin
000 979 135 E 000 979 227 E 000 979 306 000 979 407 E
1
9   4A0 972 883    4A0 972 883 qty: 1
Flat contact housing withcontact locking mechanismConnection pieceHeater with fresh air andheating control Possible single wire: F >> 1U-42830 086 F >> 1U-48724 053
  Flat contact housing withcontact locking mechanismConnection pieceHeater with fresh air andheating control Possible single wire: F >> 1U-42830 086 F >> 1U-48724 053 12 pin
000 979 018 E 000 979 018 A
1
(9)   8E0 972 112    8E0 972 112 qty: 1 || || || || || X || X
Flat contact housing withcontact locking mechanismConnection pieceHeater with fresh air andheating control Possible single wire: F 1U-42830 087>> F 1U-48724 054>> F 1U-7B006 167>>
0,5 0,5
  Flat contact housing withcontact locking mechanismConnection pieceHeater with fresh air andheating control Possible single wire: F 1U-42830 087>> F 1U-48724 054>> F 1U-7B006 167>> 12 pin
black
000 979 009 E 000 979 009 EA
1 || || || || || X || X 0,5 0,5
10   4A0 972 883 A    4A0 972 883 A qty: 1
Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls Possible single wire: F >> 1U-42830 086 F >> 1U-48724 053
2
  Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls Possible single wire: F >> 1U-42830 086 F >> 1U-48724 053 16 pin
000 979 018 E 000 979 018 A
1 2
(10)   8E0 972 416    8E0 972 416 qty: 1 || || || || || X || X
Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls Possible single wire: F 1U-42830 087>> F 1U-48724 054>> F 1U-7B006 167>>
2
  Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls Possible single wire: F 1U-42830 087>> F 1U-48724 054>> F 1U-7B006 167>> 16 pin
brown
000 979 009 E 000 979 009 EA
1 || || || || || X || X 2
11   4A0 972 883 B    4A0 972 883 B qty: 1
Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls Possible single wire: F >> 1U-42830 086 F >> 1U-48724 053
  Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls Possible single wire: F >> 1U-42830 086 F >> 1U-48724 053 20 pin
000 979 018 E 000 979 018 A
1
(11)   8E0 972 420    8E0 972 420 qty: 1 || || || || || X || X
Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls Possible single wire: F 1U-42830 087>> F 1U-48724 054>> F 1U-7B006 167>>
2
  Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls Possible single wire: F 1U-42830 087>> F 1U-48724 054>> F 1U-7B006 167>> 20 pin
red
000 979 009 E 000 979 009 EA
1 || || || || || X || X 2
12   4A0 972 883 C    4A0 972 883 C qty: 1
Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls Possible single wire:
  Flat contact housing withcontact locking mechanismConnection piecefresh airand heater controls Possible single wire: 16 pin
000 979 006 E 000 979 121 000 979 223 E
1
16   7M0 973 119    7M0 973 119 qty: X || || 1 || 2
Flat contact housingConnection piececentral flap positioning motorServomotor Possible single wire: F >> 1U-42830 086 F >> 1U-48724 053
2
  Flat contact housingConnection piececentral flap positioning motorServomotor Possible single wire: F >> 1U-42830 086 F >> 1U-48724 053 6 pin
black
000 979 009 E
X || || 1 || 2 2
(16)   6Q0 972 706    6Q0 972 706 qty: 1
Flat contact housing withcontact locking mechanismConnection piececentral flap positioning motorServomotor Possible single wire: F 1U-42830 087>> F 1U-48724 054>> F 1U-7B006 167>>
2
  Flat contact housing withcontact locking mechanismConnection piececentral flap positioning motorServomotor Possible single wire: F 1U-42830 087>> F 1U-48724 054>> F 1U-7B006 167>> 6 pin
black
000 979 009 E
1 2