Individual parts - Octavia(OCT) [EUROPA 2011 year]

Individual parts  - Octavia - oct
â„– part number information description remark unit model
wiring harness sectionfor lighting
wiring harness sectionfor lighting left
wiring harness sectionfor lighting
wiring harness sectionfor lighting left
1   1U0 971 071 D    1U0 971 071 D qty: 1
wiring harness sectionfor lighting
  wiring harness sectionfor lighting left 1
(1)   1U0 971 071 G    1U0 971 071 G qty: 1
wiring harness sectionfor lightingHalogen twin headlights withgas discharge bulb
  wiring harness sectionfor lightingHalogen twin headlights withgas discharge bulb left 1
(1)   1U0 971 071 B    1U0 971 071 B qty: 1
wiring harness sectionfor lightingfor vehicles with manuallyregulated air conditioner
  wiring harness sectionfor lightingfor vehicles with manuallyregulated air conditioner left 1
(1)   1U0 971 071 E    1U0 971 071 E qty: 1
wiring harness sectionfor lightingHalogen twin headlights withgas discharge bulbfor vehicles with manuallyregulated air conditioner
  wiring harness sectionfor lightingHalogen twin headlights withgas discharge bulbfor vehicles with manuallyregulated air conditioner left 1
(1)   1U0 971 071 C    1U0 971 071 C qty: 1
wiring harness sectionfor lightingfor vehicles with electroni-cally regulated air condit.
  wiring harness sectionfor lightingfor vehicles with electroni-cally regulated air condit. left 1
(1)   1U0 971 071 F    1U0 971 071 F qty: 1
wiring harness sectionfor lightingHalogen twin headlights withgas discharge bulbfor vehicles with electroni-cally regulated air condit.
  wiring harness sectionfor lightingHalogen twin headlights withgas discharge bulbfor vehicles with electroni-cally regulated air condit. left 1
Individual parts
Individual parts
2   1J0 906 233    1J0 906 233 qty: 1
Flat contact housingConnection pieceRadiator fan Possible single wire:
  Flat contact housingConnection pieceRadiator fan Possible single wire: 3 pin
left
000 979 131 E 000 979 227 E
1
3   1J0 906 234    1J0 906 234 qty: 1 || || || || X || X
Flat contact housingConnection pieceControl unitFor radiator fan Possible single wire:
2,5 6,0
  Flat contact housingConnection pieceControl unitFor radiator fan Possible single wire: 4 pin
000 979 227 E 000 979 412 E
1 || || || || X || X 2,5 6,0
4   1J0 906 443    1J0 906 443 qty: 1
Flat contact housingConnection pieceRadiator fan Possible single wire:
  Flat contact housingConnection pieceRadiator fan Possible single wire: 3 pin
right
000 979 228 E 000 979 307 E
1
5   1J0 937 773    1J0 937 773 qty: 1 || || || X || X || X || X
Flat contact housingConnection piecefuse holder Possible single wire:
  Flat contact housingConnection piecefuse holder Possible single wire: 3 pin
000 979 135 E 000 979 227 E 000 979 306 000 979 407 E
1 || || || X || X || X || X
6   8D0 973 734    8D0 973 734 qty: 1 || || || X || X || X || X
Flat contact housingConnection pieceHalogen headlights Possible single wire:
  Flat contact housingConnection pieceHalogen headlights Possible single wire: 8 pin
black
left
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1 || || || X || X || X || X
(6)   1J0 941 165    1J0 941 165 qty: 1 || || || || || X || X || X || X
Flat contact housing withcontact locking mechanismConnection pieceHalogen twin headlights withgas discharge bulb Possible single wire:
1,0 1,0 2,5 2,5
  Flat contact housing withcontact locking mechanismConnection pieceHalogen twin headlights withgas discharge bulb Possible single wire: 12 pin
left
000 979 131 E 000 979 131 EA 000 979 225 E 000 979 225 EA
1 || || || || || X || X || X || X 1,0 1,0 2,5 2,5
6A   1J0 973 724    1J0 973 724 qty: 1 || || || X || X || X || X
Flat contact housingHalogen twin headlights withgas discharge bulb Possible single wire:
  Flat contact housingHalogen twin headlights withgas discharge bulb Possible single wire: 4 pin
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1 || || || X || X || X || X
7   357 951 772    357 951 772 qty: 2
flat contact housing withgasketConnection pieceSignal horn Possible single wire:
  flat contact housing withgasketConnection pieceSignal horn Possible single wire: 2 pin
000 979 107 000 979 204 E 000 979 402 E
2
8   1J0 973 203    1J0 973 203 qty: 1
Flat contact housing withcontact locking mechanismConnection pieceSwitchtemperature gauge Possible single wire:
  Flat contact housing withcontact locking mechanismConnection pieceSwitchtemperature gauge Possible single wire: 3 pin
000 979 306
1
8   1H0 973 203    1H0 973 203 qty: 1
flat contact housing withgasketConnection pieceSwitchtemperature gauge Possible single wire:
  flat contact housing withgasketConnection pieceSwitchtemperature gauge Possible single wire: 3 pin
000 979 306
1
9   1J0 973 702    1J0 973 702 qty: X || || || 1 || || || 1
Flat contact housing withcontact locking mechanismConnection pieceSwitchfor vehicles with alarm systemBonnetExternal temperature sensor Possible single wire:
  Flat contact housing withcontact locking mechanismConnection pieceSwitchfor vehicles with alarm systemBonnetExternal temperature sensor Possible single wire: 2 pin
000 979 131 E 000 979 131 EA
X || || || 1 || || || 1
10   6X0 973 717    6X0 973 717 qty: 1 || || || || || X || X
Flat contact housing withcontact locking mechanismConnection pieceControl unitFor radiator fan Possible single wire:
1,0 1,0
  Flat contact housing withcontact locking mechanismConnection pieceControl unitFor radiator fan Possible single wire: 14 pin
black
000 979 131 E 000 979 131 EA
1 || || || || || X || X 1,0 1,0
11   1J0 973 722    1J0 973 722 qty: X || || || 1 || || 1
Flat contact housing withcontact locking mechanismConnection piecefor turn signalCoupling elementWiring set for three-phasealternator Possible single wire:
  Flat contact housing withcontact locking mechanismConnection piecefor turn signalCoupling elementWiring set for three-phasealternator Possible single wire: 2 pin
black
left
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
X || || || 1 || || 1
(11)   1J0 973 724    1J0 973 724 qty: 1
Flat contact housingSensor for headlight rangecontrol Possible single wire:
  Flat contact housingSensor for headlight rangecontrol Possible single wire: 4 pin
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1
12   1J0 973 724    1J0 973 724 qty: X
Flat contact housingCoupling elementWiring set for three-phasealternator Possible single wire:
  Flat contact housingCoupling elementWiring set for three-phasealternator Possible single wire: 4 pin
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
X
(12)   7M0 973 119    7M0 973 119 qty: 1 || || || || X
Flat contact housingConnection pieceSensor for headlight rangecontrol Possible single wire:
0,5
  Flat contact housingConnection pieceSensor for headlight rangecontrol Possible single wire: 6 pin
black
000 979 009 E
1 || || || || X 0,5
13   1J0 973 737    1J0 973 737 qty: 1 || || || || X || X || X
Flat contact housing withcontact locking mechanismCoupling elementWiring set for engine Possible single wire:
1,0 1,0 2,5
  Flat contact housing withcontact locking mechanismCoupling elementWiring set for engine Possible single wire: 14 pin
000 979 131 E 000 979 133 000 979 225 E
1 || || || || X || X || X 1,0 1,0 2,5
15   1J0 971 921 E    1J0 971 921 E qty: 1
Protective cap
  Protective cap 1
16   1J0 971 615 B T   1J0 971 615 B T qty: 1
Cable guide
  Cable guide 1
18   3D0 971 838 N    3D0 971 838 N qty: X
Cable ties with bracket For hole/material thickness:
  Cable ties with bracket For hole/material thickness: 4, 5X200 6, 5 / 0, 6-1, 5 X
20   N90 701 801    N90 701 801 qty: 1
Corrugated tube joiner withside opening
  Corrugated tube joiner withside opening 7, 5X7, 5X5 1
21   N90 681 901    N90 681 901 qty: X
corrugated pipe end piece
  corrugated pipe end piece 4, 5 X
(21)   N90 682 001    N90 682 001 qty: X
corrugated pipe end piece
  corrugated pipe end piece 7, 5 X
(21)   N90 682 101    N90 682 101 qty: 1
corrugated pipe end piece
  corrugated pipe end piece 10 1
(21)   N90 682 201    N90 682 201 qty: X
corrugated pipe end piece
  corrugated pipe end piece 13 X
22   1U0 972 847    1U0 972 847 qty: 1
Clip
  Clip 1
23   3D0 971 838 N    3D0 971 838 N qty: 2
Cable ties with bracket For hole/material thickness:
  Cable ties with bracket For hole/material thickness: 4, 5X200 6, 5 / 0, 6-1, 5 2