single parts whitch are not included with the p... - Octavia(OCT) [EUROPA 2012 year]

single parts whitch are not<br>included with the parts supp-<br>lied with the wiring harness  - Octavia - oct
â„– part number information description remark unit model
Central wiring set area:wiring harness: front left
Central wiring set area:wiring harness: front left
Central wiring set area:wiring harness: front leftAssoc. part -> -> -> -> -> ->
Central wiring set area:wiring harness: front leftAssoc. part -> -> -> -> -> -> 971-80 POS.1
5 Direction of travel
Direction of travel
Individual parts area:wiring harness: front left
Individual parts area:wiring harness: front left
5 Direction of travel
Direction of travel
10   1J0 973 705    1J0 973 705 qty: 1 || || || || X || X
Flat contact housing withcontact locking mechanismSwitch for clutchpedal Possible single wire:
1,0 1,0
  Flat contact housing withcontact locking mechanismSwitch for clutchpedal Possible single wire: 5 pin
000 979 131 E 000 979 131 EA
1 || || || || X || X 1,0 1,0
11 see illustration:
see illustration: 927-000
12   1J0 973 702    1J0 973 702 qty: 1
Flat contact housing withcontact locking mechanismsensor matbrake fluid Possible single wire:
  Flat contact housing withcontact locking mechanismsensor matbrake fluid Possible single wire: 2 pin
000 979 131 E 000 979 131 EA
1
13   1J0 973 733    1J0 973 733 qty: 2
Flat contact housingLambda probe Possible single wire:
PR:T53
  Flat contact housingLambda probe Possible single wire: 6 pin
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
2 PR:T53
13   1J0 973 713    1J0 973 713 qty: 1 || || || X || X
Flat contact housingLambda probe(Before starter catalyst) Possible single wire:
PR:TE6,T9G, TM0,T71,TG0, PR:TU3
  Flat contact housingLambda probe(Before starter catalyst) Possible single wire: 6 pin
black
000 979 131 E 000 979 131 EA
1 || || || X || X PR:TE6,T9G, TM0,T71,TG0, PR:TU3
14   4F0 973 705    4F0 973 705 qty: 1 || || || X || X || X || X
Flat contact housing withcontact locking mechanismAir mass meter Possible single wire:
  Flat contact housing withcontact locking mechanismAir mass meter Possible single wire: 5 pin
black
000 979 034/A 000 979 034 EC 000 979 159/A 000 979 159 EC
1 || || || X || X || X || X
14   1J0 973 999 A    1J0 973 999 A qty: 1 || || || X || X
Flat contact housing withcontact locking mechanismAir mass meter Possible single wire:
  Flat contact housing withcontact locking mechanismAir mass meter Possible single wire: 5 pin
black/blue
000 979 026 000 979 026 EA
1 || || || X || X
14   1J0 973 705    1J0 973 705 qty: 1 || || || X || X
Flat contact housing withcontact locking mechanismAir mass meter Possible single wire:
  Flat contact housing withcontact locking mechanismAir mass meter Possible single wire: 5 pin
000 979 131 E 000 979 131 EA
1 || || || X || X
14   3D0 973 703    3D0 973 703 qty: 1 || || || X || X
Flat contact housing withcontact locking mechanismAir mass meter Possible single wire:
  Flat contact housing withcontact locking mechanismAir mass meter Possible single wire: 3 pin
black
000 979 131 E 000 979 131 EA
1 || || || X || X
15   1J0 973 702    1J0 973 702 qty: 2
Flat contact housing withcontact locking mechanismSpray nozzle, heated Possible single wire:
  Flat contact housing withcontact locking mechanismSpray nozzle, heated Possible single wire: 2 pin
000 979 131 E 000 979 131 EA
2
17   4B0 973 712    4B0 973 712 qty: 1 || || || X || X
Flat contact housing withcontact locking mechanismswitch - brake light Possible single wire:
  Flat contact housing withcontact locking mechanismswitch - brake light Possible single wire: 4 pin
000 979 131 E 000 979 131 EA
1 || || || X || X
18   1J0 973 733    1J0 973 733 qty: 2
Flat contact housingVacuum pump Possible single wire:
  Flat contact housingVacuum pump Possible single wire: 6 pin
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
2
19   1J0 973 704    1J0 973 704 qty: 1 || || || X
Flat contact housing withcontact locking mechanismPressure sender Possible single wire:
  Flat contact housing withcontact locking mechanismPressure sender Possible single wire: 4 pin
000 979 131 E 000 979 131 EA
1 || || || X
20   1J0 973 713    1J0 973 713 qty: 1 || || X || X
Flat contact housingsolenoid valve block Possible single wire:
1,0 1,0
  Flat contact housingsolenoid valve block Possible single wire: 6 pin
black
000 979 131 E 000 979 131 EA
1 || || X || X 1,0 1,0
21   1J0 973 702    1J0 973 702 qty: 1
Flat contact housing withcontact locking mechanismTemperature sensor Possible single wire:
DPF
  Flat contact housing withcontact locking mechanismTemperature sensor Possible single wire: 2 pin
000 979 131 E 000 979 131 EA
1 DPF
21   1J0 973 702 A    1J0 973 702 A qty: 1 || || || X || X
Flat contact housing withcontact locking mechanismTemperature sensor Possible single wire: counterpart to:
DPF
  Flat contact housing withcontact locking mechanismTemperature sensor Possible single wire: counterpart to: 2 pin
brown
000 979 131 E 000 979 131 EA 6X0 973 802 A
1 || || || X || X DPF
21   1J0 973 702 C    1J0 973 702 C qty: 1 || || || X || X
Flat contact housing withcontact locking mechanismTemperature sensor Possible single wire:
DPF
  Flat contact housing withcontact locking mechanismTemperature sensor Possible single wire: 2 pin
orange
000 979 131 E 000 979 131 EA
1 || || || X || X DPF
24   1J0 973 722    1J0 973 722 qty: 1
Flat contact housing withcontact locking mechanismPressure converter Possible single wire:
  Flat contact housing withcontact locking mechanismPressure converter Possible single wire: 2 pin
black
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1
25   1J0 973 722    1J0 973 722 qty: 1
Flat contact housing withcontact locking mechanismheater pipefor vehicle use in coldclimates Possible single wire:
  Flat contact housing withcontact locking mechanismheater pipefor vehicle use in coldclimates Possible single wire: 2 pin
black
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1
26   1J0 973 724    1J0 973 724 qty: 1 || || X || X || X || X
Flat contact housingWiper motor Possible single wire:
  Flat contact housingWiper motor Possible single wire: 4 pin
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1 || || X || X || X || X
27   4E0 972 781    4E0 972 781 qty: 1 || || || || X || X
flat contact housing withcapControl unit for petrol engineControl unit for diesel engineControl unit Possible single wire:
PR:T53
  flat contact housing withcapControl unit for petrol engineControl unit for diesel engineControl unit Possible single wire: 81-pin
black
000 979 225 E 000 979 133
1 || || || || X || X PR:T53
27   1J0 906 380 B    1J0 906 380 B qty: 1
flat contact housing withgasketControl unit Possible single wire:
PR:TT1
  flat contact housing withgasketControl unit Possible single wire: 52 pin
000 979 131 E 000 979 131 EA
1 PR:TT1
27   3C0 906 385    3C0 906 385 qty: 1 || || || || X || X
Flat contact housing withcontact locking mechanismControl unit for petrol engineControl unit for diesel engine Possible single wire:
PR:TU0,TE6, TD6,TF3,T71, TG0,T9G,TM0, TU3
  Flat contact housing withcontact locking mechanismControl unit for petrol engineControl unit for diesel engine Possible single wire: 94-pin
000 979 030 E 000 979 242 E
1 || || || || X || X PR:TU0,TE6, TD6,TF3,T71, TG0,T9G,TM0, TU3
28   1J0 973 704    1J0 973 704 qty: 1 || || || || X
Flat contact housing withcontact locking mechanismLambda probe(behind catalyst) Possible single wire:
PR:TT1,T53, TE6
  Flat contact housing withcontact locking mechanismLambda probe(behind catalyst) Possible single wire: 4 pin
000 979 131 E 000 979 131 EA
1 || || || || X PR:TT1,T53, TE6
29 see illustration:
see illustration: 937-000
30   038 973 721 B    038 973 721 B qty: 1
Flat contact housing withcontact locking mechanismControl unit for glow plug Possible single wire:
1,0. 2,5 2,5
  Flat contact housing withcontact locking mechanismControl unit for glow plug Possible single wire: 11 pin
000 979 133 000 979 225 E 000 979 227 E
1 1,0. 2,5 2,5
31   3C0 973 721    3C0 973 721 qty: 1 || X || X
relay plate Possible single wire:No replacement part
  relay plate Possible single wire:No replacement part 4 pin
000 979 027 E 000 979 417 E 10 MM²
1 || X || X
32   6R0 973 735    6R0 973 735 qty: 1 || || || X
Flat contact housingHalogen headlights Possible single wire:
  Flat contact housingHalogen headlights Possible single wire: 10 pin
black
000 979 131 E 000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1 || || || X
32   1J0 973 737    1J0 973 737 qty: 1 || || || || X || X || X
Flat contact housing withcontact locking mechanismHead light with gas dischargelamp Possible single wire: matching contact housing:Before parts order, physical inspection ofold part necessary
  Flat contact housing withcontact locking mechanismHead light with gas dischargelamp Possible single wire: matching contact housing:Before parts order, physical inspection ofold part necessary 14 pin
000 979 131 E 000 979 133 000 979 225 E 1J0 973 837
1 || || || || X || X || X
32   3C0 973 737    3C0 973 737 qty: 1 || || || || X || X || X || X || X
Flat contact housing withcontact locking mechanismHead light with gas dischargelamp Possible single wire: matching contact housing:Before parts order, physical inspection ofold part necessary
0,5 0,5 1,0 1,0 2,5
  Flat contact housing withcontact locking mechanismHead light with gas dischargelamp Possible single wire: matching contact housing:Before parts order, physical inspection ofold part necessary 14 pin
000 979 025/A 000 979 026/A 000 979 150/A 000 979 151/A 000 979 242/A 3C0 973 837
1 || || || || X || X || X || X || X 0,5 0,5 1,0 1,0 2,5
33   6R0 973 735    6R0 973 735 qty: 1 || || || X
Flat contact housingWiring set for engine Possible single wire:
  Flat contact housingWiring set for engine Possible single wire: 10 pin
black
000 979 131 E 000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1 || || || X
33   1J0 973 737    1J0 973 737 qty: 1 || || || X || X || X
Flat contact housing withcontact locking mechanismWiring set for engine Possible single wire:
  Flat contact housing withcontact locking mechanismWiring set for engine Possible single wire: 14 pin
000 979 131 E 000 979 133 000 979 225 E
1 || || || X || X || X
34   1J0 906 380 B    1J0 906 380 B qty: 1
flat contact housing withgasketControl unit for automaticgearboxControl unit Possible single wire:
  flat contact housing withgasketControl unit for automaticgearboxControl unit Possible single wire: 52 pin
000 979 131 E 000 979 131 EA
1
35   1J0 973 713    1J0 973 713 qty: 1 || || X || X
Flat contact housingWiring set for Servotronic Possible single wire:
1,0 1,0
  Flat contact housingWiring set for Servotronic Possible single wire: 6 pin
black
000 979 131 E 000 979 131 EA
1 || || X || X 1,0 1,0
37   6X0 973 802 A    6X0 973 802 A qty: 1 || || || || X || X
Flat contact housing withcontact locking mechanismWiring set for three-phasealternator Possible single wire: counterpart to:
  Flat contact housing withcontact locking mechanismWiring set for three-phasealternator Possible single wire: counterpart to: 2 pin
dark brown
000 979 132 E 000 979 132 EA 1J0 973 702 A
1 || || || || X || X
37   1K0 973 804    1K0 973 804 qty: 1 || || || || X || X
Flat contact housing withcontact locking mechanismWiring set for three-phasealternator Possible single wire: counterpart to:
  Flat contact housing withcontact locking mechanismWiring set for three-phasealternator Possible single wire: counterpart to: 4 pin
black
000 979 132 E 000 979 132 EA 1J0 973 704
1 || || || || X || X
38   1J0 973 702    1J0 973 702 qty: 1
Flat contact housing withcontact locking mechanismTemperature sensorCooler for coolant Possible single wire:
  Flat contact housing withcontact locking mechanismTemperature sensorCooler for coolant Possible single wire: 2 pin
000 979 131 E 000 979 131 EA
1
39   1K0 906 234    1K0 906 234 qty: 1 || || X || X
Flat contact housingRadiator fan Possible single wire: counterpart to:
2,5 6,0
  Flat contact housingRadiator fan Possible single wire: counterpart to: 4 pin
000 979 249 E 000 979 417 E 1J0 906 444
1 || || X || X 2,5 6,0
40   4D0 971 992    4D0 971 992 qty: 1 || || || X
Flat connector housing withcontact locking mechanismFanfare Possible single wire:
1,0
  Flat connector housing withcontact locking mechanismFanfare Possible single wire: 2 pin
000 979 141 E
1 || || || X 1,0
41   1J0 973 722    1J0 973 722 qty: 1
Flat contact housing withcontact locking mechanismfor fog lampFor day driving lights Possible single wire:
  Flat contact housing withcontact locking mechanismfor fog lampFor day driving lights Possible single wire: 2 pin
black
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1
41   3D0 941 165 A    3D0 941 165 A qty: 1
Flat contact housingfor fog lampHalogen fog lights withstatic cornering light Possible single wire:
  Flat contact housingfor fog lampHalogen fog lights withstatic cornering light Possible single wire: 000 979 244 E 1
41   1J0 973 722    1J0 973 722 qty: 1
Flat contact housing withcontact locking mechanismfor fog lamp Possible single wire: D >> - 24.05.2009
RS SCOUT
  Flat contact housing withcontact locking mechanismfor fog lamp Possible single wire: D >> - 24.05.2009 2 pin
black
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1 RS SCOUT
41   7H0 941 165    7H0 941 165 qty: 1 || || || X
Flat contact housing withcontact locking mechanismfor fog lamp Possible single wire: D - 25.05.2009>>
RS SCOUT
  Flat contact housing withcontact locking mechanismfor fog lamp Possible single wire: D - 25.05.2009>> 2 pin
black
000 979 244 E
1 || || || X RS SCOUT
41   1J0 973 723    1J0 973 723 qty: 1 || || || X
flat contact housing withgasketLED day lights Possible single wire: 2 D - 25.05.2009>>
RS
  flat contact housing withgasketLED day lights Possible single wire: 2 D - 25.05.2009>> 3 pin
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1 || || || X RS
42   1J0 973 702    1J0 973 702 qty: 1
Flat contact housing withcontact locking mechanismTemperature sensor Possible single wire:
  Flat contact housing withcontact locking mechanismTemperature sensor Possible single wire: 2 pin
000 979 131 E 000 979 131 EA
1
43   6R0 973 735    6R0 973 735 qty: 1 || || || X
Flat contact housingfor automatic gearbox Possible single wire:
  Flat contact housingfor automatic gearbox Possible single wire: 10 pin
black
000 979 131 E 000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1 || || || X
44   1J0 973 714    1J0 973 714 qty: 1
Flat contact housingfor automatic gearbox
  Flat contact housingfor automatic gearbox 8 pin 1
45   6X0 973 717    6X0 973 717 qty: 1 || || || X || X
Flat contact housing withcontact locking mechanismfor automatic gearbox Possible single wire:
1,0 1,0
  Flat contact housing withcontact locking mechanismfor automatic gearbox Possible single wire: 14 pin
black
000 979 131 E 000 979 131 EA
1 || || || X || X 1,0 1,0
46   1J0 973 702    1J0 973 702 qty: 1
Flat contact housing withcontact locking mechanismswitch for reversing light Possible single wire:
  Flat contact housing withcontact locking mechanismswitch for reversing light Possible single wire: 2 pin
000 979 131 E 000 979 131 EA
1
47   1K0 973 751    1K0 973 751 qty: 1 || || X
flat contact housing withgasketStarter Possible single wire:
  flat contact housing withgasketStarter Possible single wire: 1 pin
black
000 979 243 E
1 || || X
48   1J0 973 722    1J0 973 722 qty: 1
Flat contact housing withcontact locking mechanismWiring set for three-phasealternator Possible single wire:
  Flat contact housing withcontact locking mechanismWiring set for three-phasealternator Possible single wire: 2 pin
black
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1
49   1J0 973 724    1J0 973 724 qty: 1 || || || X || X || X || X
Flat contact housingWiring set for three-phasealternator Possible single wire:
  Flat contact housingWiring set for three-phasealternator Possible single wire: 4 pin
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
1 || || || X || X || X || X
49   1J0 973 704    1J0 973 704 qty: 1 || || || X
Flat contact housing withcontact locking mechanismPressure sender Possible single wire:
  Flat contact housing withcontact locking mechanismPressure sender Possible single wire: 4 pin
000 979 131 E 000 979 131 EA
1 || || || X
50   1K0 973 213    1K0 973 213 qty: 1 || || || X || X || X || X || X
Flat contact housing withcontact locking mechanismfor automatic gearbox Possible single wire:
7 speed
automatic
  Flat contact housing withcontact locking mechanismfor automatic gearbox Possible single wire: 25 pin
black
000 979 025/A 000 979 027/C 000 979 152/C 000 979 243/C 000 979 308/C
1 || || || X || X || X || X || X 7 speed
automatic
50   1J0 927 320    1J0 927 320 qty: 1
Round connector housing withcontact locking mechanismfor automatic gearbox Possible single wire:
6-speed
automatic
  Round connector housing withcontact locking mechanismfor automatic gearbox Possible single wire: 20 pin
000 979 154 E
1 6-speed
automatic
51   1J0 973 713    1J0 973 713 qty: 1 || || || X || X
Flat contact housingLambda probe(Before starter catalyst) Possible single wire:
PR:TU0
  Flat contact housingLambda probe(Before starter catalyst) Possible single wire: 6 pin
black
000 979 131 E 000 979 131 EA
1 || || || X || X PR:TU0
51   1J0 973 704    1J0 973 704 qty: 1 || || || || X
Flat contact housing withcontact locking mechanismLambda probe(behind catalyst) Possible single wire:
PR:TU0
  Flat contact housing withcontact locking mechanismLambda probe(behind catalyst) Possible single wire: 4 pin
000 979 131 E 000 979 131 EA
1 || || || || X PR:TU0
51   6Q0 973 704 A    6Q0 973 704 A qty: 1 || || || || X || X
Flat contact housing withcontact locking mechanismLambda probe(Before starter catalyst) Possible single wire:
PR:TT1
  Flat contact housing withcontact locking mechanismLambda probe(Before starter catalyst) Possible single wire: 4 pin
brown
000 979 131 E 000 979 131 EA
1 || || || || X || X PR:TT1
52   1J0 973 752    1J0 973 752 qty: 1 || || || X
Flat contact housing withcontact locking mechanismSecondary air pump Possible single wire: counterpart to:
  Flat contact housing withcontact locking mechanismSecondary air pump Possible single wire: counterpart to: 2 pin
000 979 135 E 000 979 227 E 1J0 973 852
1 || || || X
53   1J0 973 733    1J0 973 733 qty: 2
Flat contact housingVacuum pump Possible single wire:
PR:T53
  Flat contact housingVacuum pump Possible single wire: 6 pin
000 979 133 000 979 133 EA 000 979 225 E 000 979 225 EA
2 PR:T53
80   1K0 971 915 D    1K0 971 915 D qty: 1
Grommet
  Grommet left 1
81   N10 436 401    N10 436 401 qty: 1
Bracket
  Bracket 8X4, 5 1
82   6X0 971 921 C    6X0 971 921 C qty: X
Protective capFlat contact housing
  Protective capFlat contact housing 5 pin X
83   N91 115 901    N91 115 901 qty: X
Bundling clip f wiring harness For hole/material thickness:
  Bundling clip f wiring harness For hole/material thickness: 6, 5/0, 6-5MM X
84   1U0 971 848 A    1U0 971 848 A qty: 1
Cable holder
  Cable holder 1
85   1K0 971 921 B    1K0 971 921 B qty: 1
Bracket protective cover
  Bracket protective cover 5 pinblack 1
87   1J0 971 798 C    1J0 971 798 C qty: 1
sealing tape
  sealing tape 220X60X4 1
88   1Z0 971 615 A    1Z0 971 615 A qty: 1
Cable guide
  Cable guide 1
90   1J0 971 798 C    1J0 971 798 C qty: 1
sealing tape
  sealing tape 220X60X4 1
91   1T0 971 930 E    1T0 971 930 E qty: 1
Bundling clip f wiring harness
  Bundling clip f wiring harness 1
92   N90 681 301    N90 681 301 qty: 1
bracket for corrugated pipe
  bracket for corrugated pipe A4, 5 1
93   N90 643 701    N90 643 701 qty: X
Cable tie with holder for weld pin:
  Cable tie with holder for weld pin: 10X187 5MM X
94   3D0 971 838 N    3D0 971 838 N qty: 1
Cable ties with brackettoothed quadrant For hole/material thickness:
  Cable ties with brackettoothed quadrant For hole/material thickness: outer
6, 5 / 0, 3-3
1
95   8L0 971 848 D    8L0 971 848 D qty: X
Cable holder
  Cable holder X
96   3D0 971 838 N    3D0 971 838 N qty: 1
Cable ties with brackettoothed quadrant For hole/material thickness:
  Cable ties with brackettoothed quadrant For hole/material thickness: outer
6, 5 / 0, 3-3
1
97   6H0 971 921 C    6H0 971 921 C qty: 1
Bracket protective coverConnection pieceFlat contact housing
  Bracket protective coverConnection pieceFlat contact housing 2 pin 1
98   3D0 971 838 N    3D0 971 838 N qty: 1
Cable ties with brackettoothed quadrant For hole/material thickness:
  Cable ties with brackettoothed quadrant For hole/material thickness: outer
6, 5 / 0, 3-3
1
99   N10 517 801    N10 517 801 qty: 1
Cable holder
  Cable holder 8X13 1
100   N90 669 201    N90 669 201 qty: 1
corrugated pipe t piece
  corrugated pipe t piece 13-10-10 1
101   6H0 971 921 A    6H0 971 921 A qty: 1
Protective cap
  Protective cap 1
103   N90 815 401    N90 815 401 qty: 1
Junction
  Junction 7, 5-4, 5-4, 5 1
104   6X0 971 921 D    6X0 971 921 D qty: X
Protective capFlat contact housing
  Protective capFlat contact housing 1J0 973 704 X
105   1E0 971 921    1E0 971 921 qty: 1
Bracket protective cover
  Bracket protective cover 1
106   3D0 971 838 N    3D0 971 838 N qty: 1
Cable ties with brackettoothed quadrant For hole/material thickness:
  Cable ties with brackettoothed quadrant For hole/material thickness: outer
6, 5 / 0, 3-3
1
107   N90 697 901    N90 697 901 qty: 1
bracket for corrugated pipe
  bracket for corrugated pipe 13 1
108   1J0 971 921 N    1J0 971 921 N qty: 1
Protective cap
  Protective cap 6 pin 1
109   1K0 971 848 N    1K0 971 848 N qty: 1
Cable holder
  Cable holder 1
single parts whitch are notincluded with the parts supp-lied with the wiring harness
single parts whitch are notincluded with the parts supp-lied with the wiring harness
150   1K0 971 615 D A   1K0 971 615 D A qty: 1
Cable guideSide member
Manual
gearbox6-speed
automatic
  Cable guideSide member 1 Manual
gearbox6-speed
automatic
150   1K0 971 615 D B   1K0 971 615 D B qty: 1
Cable guideSide member D >> - 13.12.2009
7 speed
automatic
  Cable guideSide member D >> - 13.12.2009 1 7 speed
automatic
150   1K0 971 615 D E   1K0 971 615 D E qty: 1
Cable guideSide member D - 14.12.2009>>
7 speed
automatic
  Cable guideSide member D - 14.12.2009>> 1 7 speed
automatic
151   1K2 971 615 A    1K2 971 615 A qty: 1
Cable guidegearbox mounting
  Cable guidegearbox mounting 1
152   1C0 422 705 A    1C0 422 705 A qty: 2
Clip
  Clip 2
153   1K0 941 057    1K0 941 057 qty: 1
bracket for connector housingFanfare
  bracket for connector housingFanfare 1
154   1J0 971 260 E    1J0 971 260 E qty: 1
Anti-twist deviceEarth lineBattery
  Anti-twist deviceEarth lineBattery 1
-   5J0 971 658    5J0 971 658 qty: 1
part section wiring harness
  part section wiring harness TRANSIL 1