| | | | Onboard supply control unitcentral electrics, fuse box, relay carrier, relays | | Onboard supply control unitcentral electrics, fuse box, relay carrier, relays | | | |
| | | | Onboard supply control unitDiagnosis interface fordata bus (Gateway) | | Onboard supply control unitDiagnosis interface fordata bus (Gateway) | | | |
| | 1 | | Before parts order, physical inspection ofold part necessary PR:7LA | | Before parts order, physical inspection ofold part necessary | | | PR:7LA |
| | 1 | 1K0 937 087 A D | 1K0 937 087 A D qty: 1 || || || || 1 Control unit (BCM) forconv. system & OB power supplyfor models withfog lamps D - 28.05.2012>> PR:4R4+GP3 | | Control unit (BCM) forconv. system & OB power supplyfor models withfog lamps D - 28.05.2012>> | | 1 || || || || 1 | PR:4R4+GP3 |
| | | 1K0 937 087 A DZ00 | 1K0 937 087 A DZ00 Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> | | Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> | | | |
| | (1) | 1K0 937 086 R | 1K0 937 086 R qty: 1 || || || || 1 Control unit (BCM) forconv. system & OB power supplyfor models withfog lamps D - 28.05.2012>> PR:4R4+GP0 | | Control unit (BCM) forconv. system & OB power supplyfor models withfog lamps D - 28.05.2012>> | | 1 || || || || 1 | PR:4R4+GP0 |
| | | 1K0 937 086 R Z00 | 1K0 937 086 R Z00 Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> | | Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> | | | |
| | (1) | 1K0 937 086 N | 1K0 937 086 N qty: 1 || || || || 1 Control unit (BCM) forconv. system & OB power supplyfor models withfog lamps D - 30.05.2011>> - 27.05.2012 PR:4R0,4R5+ +GP0 | | Control unit (BCM) forconv. system & OB power supplyfor models withfog lamps D - 30.05.2011>> - 27.05.2012 | | 1 || || || || 1 | PR:4R0,4R5+ +GP0 |
| | (1) | 1K0 937 086 S | 1K0 937 086 S qty: 1 Control unit (BCM) forconv. system & OB power supplyfor models withfog lamps D - 28.05.2012>> PR:4R0,4R5+ +GP0 | | Control unit (BCM) forconv. system & OB power supplyfor models withfog lamps D - 28.05.2012>> | | 1 | PR:4R0,4R5+ +GP0 |
| | | 1K0 937 086 S Z00 | 1K0 937 086 S Z00 Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> | | Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> | | | |
| | (1) | 1K0 937 087 A E | 1K0 937 087 A E qty: 1 Control unit (BCM) forconv. system & OB power supplyfor models withfog lamps D - 28.05.2012>> PR:4R5,4R0+ GP3 | | Control unit (BCM) forconv. system & OB power supplyfor models withfog lamps D - 28.05.2012>> | | 1 | PR:4R5,4R0+ GP3 |
| | | 1K0 937 087 A EZ00 | 1K0 937 087 A EZ00 Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> | | Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> | | | |
| | (1) | 1K0 937 084 H | 1K0 937 084 H qty: 1 Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> - 27.05.2013 PR:4R4+8WA | | Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> - 27.05.2013 | | 1 | PR:4R4+8WA |
| | | 1K0 937 084 H Z00 | 1K0 937 084 H Z00 Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> - 27.05.2013 PR:4R4+8WA+ GP0,GP3 | | Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> - 27.05.2013 | | | PR:4R4+8WA+ GP0,GP3 |
| | (1) | 1K0 937 085 P | 1K0 937 085 P qty: 1 Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> PR:4R5,4R0+ +8WA+GP0,GP3 | | Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> | | 1 | PR:4R5,4R0+ +8WA+GP0,GP3 |
| | | 1K0 937 085 P Z00 | 1K0 937 085 P Z00 Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> | | Control unit (BCM) forconv. system & OB power supply D - 28.05.2012>> | | | |
| | (1) | 1K0 937 087 H | 1K0 937 087 H qty: 1 Control unit (BCM) forconv. system & OB power supply only to be used for: | | Control unit (BCM) forconv. system & OB power supply only to be used for: | 1K0937084, D 1K0937085, D 1K0937086, A, C1K0937086D, F, G 1K0937087, A, D1K0937087E | 1 | |
| | (1) | 1K0 937 087 P | 1K0 937 087 P qty: 1 Control unit (BCM) forconv. system & OB power supply only to be used for: | | Control unit (BCM) forconv. system & OB power supply only to be used for: | 1K0 937 084 D 1K0 937 085 H 1K0 937 086 H 1K0 937 086 J 1K0 937 087 J 1K0 937 087 K | 1 | |
| | (1) | 1K0 937 087 A B | 1K0 937 087 A B qty: 1 Control unit (BCM) forconv. system & OB power supply only to be used for: | | Control unit (BCM) forconv. system & OB power supply only to be used for: | 1K0937084F 1K0937085L 1K0937086M 1K0937086N 1K0937087Q 1K0937087R | 1 | |
| | 1A | 7N0 907 530 H | 7N0 907 530 H qty: 1 Diagnosis interface fordata bus (Gateway) D >> - 06.11.2011 | | Diagnosis interface fordata bus (Gateway) D >> - 06.11.2011 | | 1 | |
| | (1A) | 7N0 907 530 H | 7N0 907 530 H qty: 1 Diagnosis interface fordata bus (Gateway) D - 30.05.2011>> - 06.11.2011 | | Diagnosis interface fordata bus (Gateway) D - 30.05.2011>> - 06.11.2011 | | 1 | |
| | (1A) | 7N0 907 530 M | 7N0 907 530 M qty: 1 Diagnosis interface fordata bus (Gateway) D - 07.11.2011>> - 27.05.2012 | | Diagnosis interface fordata bus (Gateway) D - 07.11.2011>> - 27.05.2012 | | 1 | |
| | (1A) | 7N0 907 530 R | 7N0 907 530 R qty: 1 Diagnosis interface fordata bus (Gateway) D - 28.05.2012>> - 30.09.2012 | | Diagnosis interface fordata bus (Gateway) D - 28.05.2012>> - 30.09.2012 | | 1 | |
| | (1A) | 7N0 907 530 A B | 7N0 907 530 A B qty: 1 Diagnosis interface fordata bus (Gateway) D - 01.10.2012>> - 02.12.2012 | | Diagnosis interface fordata bus (Gateway) D - 01.10.2012>> - 02.12.2012 | | 1 | |
| | (1A) | 7N0 907 530 A F | 7N0 907 530 A F qty: 1 Diagnosis interface fordata bus (Gateway) D - 03.12.2012>> | | Diagnosis interface fordata bus (Gateway) D - 03.12.2012>> | | 1 | |
| | | 7N0 907 530 A FZ00 | 7N0 907 530 A FZ00 Diagnosis interface fordata bus (Gateway) D - 03.12.2012>> | | Diagnosis interface fordata bus (Gateway) D - 03.12.2012>> | | | |
| | (1A) | 7N0 907 530 D | 7N0 907 530 D qty: 1 Diagnosis interface fordata bus (Gateway) D >> - 29.05.2011 PR:7L6 | | Diagnosis interface fordata bus (Gateway) D >> - 29.05.2011 | | 1 | PR:7L6 |
| | (1A) | 7N0 907 530 J | 7N0 907 530 J qty: 1 Diagnosis interface fordata bus (Gateway) D - 30.05.2011>> - 06.11.2011 PR:7L6 | | Diagnosis interface fordata bus (Gateway) D - 30.05.2011>> - 06.11.2011 | | 1 | PR:7L6 |
| | (1A) | 7N0 907 530 N | 7N0 907 530 N qty: 1 Diagnosis interface fordata bus (Gateway) D - 07.11.2011>> - 27.05.2012 PR:7L6 | | Diagnosis interface fordata bus (Gateway) D - 07.11.2011>> - 27.05.2012 | | 1 | PR:7L6 |
| | (1A) | 7N0 907 530 S | 7N0 907 530 S qty: 1 Diagnosis interface fordata bus (Gateway) D - 28.05.2012>> - 30.09.2012 PR:7L6 | | Diagnosis interface fordata bus (Gateway) D - 28.05.2012>> - 30.09.2012 | | 1 | PR:7L6 |
| | (1A) | 7N0 907 530 A C | 7N0 907 530 A C qty: 1 Diagnosis interface fordata bus (Gateway) D - 01.10.2012>> - 02.12.2012 PR:7L6 | | Diagnosis interface fordata bus (Gateway) D - 01.10.2012>> - 02.12.2012 | | 1 | PR:7L6 |
| | (1A) | 7N0 907 530 A G | 7N0 907 530 A G qty: 1 Diagnosis interface fordata bus (Gateway) D - 03.12.2012>> PR:7L6 | | Diagnosis interface fordata bus (Gateway) D - 03.12.2012>> | | 1 | PR:7L6 |
| | | 7N0 907 530 A GZ00 | 7N0 907 530 A GZ00 Diagnosis interface fordata bus (Gateway) D - 03.12.2012>> | | Diagnosis interface fordata bus (Gateway) D - 03.12.2012>> | | | |
| | | | FastenersRelay | | FastenersRelay | | | |
| | 2 | 1K1 937 503 | 1K1 937 503 qty: 1 relay plate D >> - 30.05.2010 | | relay plate D >> - 30.05.2010 | lhdupper | 1 | |
| | (2) | 1K1 937 503 A | 1K1 937 503 A qty: 1 relay plate D - 31.05.2010>> | | relay plate D - 31.05.2010>> | lhdupper | 1 | |
| | (2) | 1K2 937 503 A | 1K2 937 503 A qty: 1 relay plate D >> - 30.05.2010 | | relay plate D >> - 30.05.2010 | rhdupper | 1 | |
| | (2) | 1K2 937 503 B | 1K2 937 503 B qty: 1 relay plate D - 31.05.2010>> | | relay plate D - 31.05.2010>> | rhdupper | 1 | |
| | (3) | 1K0 937 503 A | 1K0 937 503 A qty: 1 relay plate D >> - 30.05.2010 | | relay plate D >> - 30.05.2010 | 5 pointlower | 1 | |
| | (3) | 7N0 937 503 A | 7N0 937 503 A qty: 1 relay plate D - 31.05.2010>> | | relay plate D - 31.05.2010>> | 5 pointlower | 1 | |
| | 4 | 4H0 951 253 | 4H0 951 253 qty: 1 Relay relay location/code no.: to be used for code no.: | | Relay relay location/code no.: to be used for code no.: | 1/644 /100 | 1 | |
| | 5 | 4H0 951 253 A | 4H0 951 253 A qty: 1 Relay relay location/code no.: to be used for code no.: | | Relay relay location/code no.: to be used for code no.: | 2/645 /373 | 1 | |
| | 6 | 4H0 951 253 C | 4H0 951 253 C qty: 1 RelaySignal horn relay location/code no.: to be used for code no.: D >> - 30.05.2010 | | RelaySignal horn relay location/code no.: to be used for code no.: D >> - 30.05.2010 | 3.1/646 /395 | 1 | |
| | (6) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relayheadlight washer system relay location/code no.: to be used for code no.: D >> - 30.05.2010 | | Relayheadlight washer system relay location/code no.: to be used for code no.: D >> - 30.05.2010 | 3.2/646 /395 | 1 | |
| | (6) | 4H0 951 253 A | 4H0 951 253 A qty: 1 Relay relay location/code no.: D - 31.05.2010>> | | Relay relay location/code no.: D - 31.05.2010>> | 3/645 | 1 | |
| | 7 | 4H0 951 253 A | 4H0 951 253 A qty: 1 Relay relay location/code no.: to be used for code no.: D >> - 30.05.2010 | | Relay relay location/code no.: to be used for code no.: D >> - 30.05.2010 | 4/645 /373 | 1 | |
| | (7) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: D - 31.05.2010>> BSE,BSF,CMXA CHGA CAYC BJB,BXE AZV,BKD CFHF CLCA,CLCB CLCB,CFHC CEGA | | Relay relay location/code no.: D - 31.05.2010>> | 4/646 | 1 | BSE,BSF,CMXA CHGA CAYC BJB,BXE AZV,BKD CFHF CLCA,CLCB CLCB,CFHC CEGA |
| | 8 | 4H0 951 253 | 4H0 951 253 qty: 1 Relay relay location/code no.: to be used for code no.: | | Relay relay location/code no.: to be used for code no.: | 5/644 100 | 1 | |
| | 10 | 4H0 951 253 A | 4H0 951 253 A qty: 1 Relay relay location/code no.: to be used for code no.: PR:9M1,9M9 | | Relay relay location/code no.: to be used for code no.: | 1/645 /373 | 1 | PR:9M1,9M9 |
| | (10) | 4H0 951 253 A | 4H0 951 253 A qty: 1 Relay relay location/code no.: to be used for code no.: PR:7E6 | | Relay relay location/code no.: to be used for code no.: | 1st stage 1/645 /373 | 1 | PR:7E6 |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: to be used for code no.: D >> - 02.11.2009 CAYC BJB,BXE,BLS CHWA AZV,BKD,BMM CEGA PR:9M1 | | Relay relay location/code no.: to be used for code no.: D >> - 02.11.2009 | 2A/646 /449 | 1 | CAYC BJB,BXE,BLS CHWA AZV,BKD,BMM CEGA PR:9M1 |
| | (10A) | 4H0 951 253 | 4H0 951 253 qty: 1 Relay relay location/code no.: to be used for code no.: D >> - 02.11.2009 | | Relay relay location/code no.: to be used for code no.: D >> - 02.11.2009 | 2B/644 /395/100 | 1 | |
| | (10) | 4H0 951 253 | 4H0 951 253 qty: 1 Relay relay location/code no.: to be used for code no.: D >> - 02.11.2009 | | Relay relay location/code no.: to be used for code no.: D >> - 02.11.2009 | 2nd stage 2/644 /370 | 1 | |
| | (10) | 4H0 951 253 | 4H0 951 253 qty: 1 Relay relay location/code no.: to be used for code no.: D >> - 02.11.2009 | | Relay relay location/code no.: to be used for code no.: D >> - 02.11.2009 | 50A 3/644 /370 | 1 | |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: to be used for code no.: D >> - 02.11.2009 CAYC BJB,BXE,BLS CHWA AZV,BKD,BMM CEGA PR:9M1 | | Relay relay location/code no.: to be used for code no.: D >> - 02.11.2009 | 4A/646 /395 | 1 | CAYC BJB,BXE,BLS CHWA AZV,BKD,BMM CEGA PR:9M1 |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: to be used for code no.: D >> - 02.11.2009 CGGA BSE,BSF,CMXA CMXA CEGA | | Relay relay location/code no.: to be used for code no.: D >> - 02.11.2009 | 4B/646 /395 | 1 | CGGA BSE,BSF,CMXA CMXA CEGA |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: to be used for code no.: D - 03.11.2009>> - 07.10.2010 CAYC | | Relay relay location/code no.: to be used for code no.: D - 03.11.2009>> - 07.10.2010 | 2/646 /449 | 1 | CAYC |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: to be used for code no.: D - 03.11.2009>> - 30.05.2010 CAYC BJB,BXE,BLS CHWA AZV,BKD,BMM CEGA CLCA,CLCB PR:9M1 | | Relay relay location/code no.: to be used for code no.: D - 03.11.2009>> - 30.05.2010 | 3A/646 /449 | 1 | CAYC BJB,BXE,BLS CHWA AZV,BKD,BMM CEGA CLCA,CLCB PR:9M1 |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: to be used for code no.: D - 03.11.2009>> - 30.05.2010 | | Relay relay location/code no.: to be used for code no.: D - 03.11.2009>> - 30.05.2010 | 3B/644 /395/100 | 1 | |
| | (10) | 4H0 951 253 | 4H0 951 253 qty: 1 Relay relay location/code no.: to be used for code no.: D - 03.11.2009>> - 30.05.2010 | | Relay relay location/code no.: to be used for code no.: D - 03.11.2009>> - 30.05.2010 | 2nd stage 3/644 /370 | 1 | |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: to be used for code no.: D - 03.11.2009>> - 30.05.2010 CAYC BJB,BXE,BLS CHWA AZV,BKD,BMM CEGA CLCA,CLCB PR:9M1 | | Relay relay location/code no.: to be used for code no.: D - 03.11.2009>> - 30.05.2010 | 4A/646 /395 | 1 | CAYC BJB,BXE,BLS CHWA AZV,BKD,BMM CEGA CLCA,CLCB PR:9M1 |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: to be used for code no.: D - 03.11.2009>> - 30.05.2010 CGGA BSE,BSF,CMXA CMXA CEGA | | Relay relay location/code no.: to be used for code no.: D - 03.11.2009>> - 30.05.2010 | 4B/646 /395 | 1 | CGGA BSE,BSF,CMXA CMXA CEGA |
| | (10) | 7N0 951 253 | 7N0 951 253 qty: 1 Relay relay location/code no.: to be used for code no.: D - 03.11.2010>> - 29.05.2011 PR:7L6 | | Relay relay location/code no.: to be used for code no.: D - 03.11.2010>> - 29.05.2011 | 2/507 | 1 | PR:7L6 |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 RelaySignal horn relay location/code no.: D - 30.05.2011>> | | RelaySignal horn relay location/code no.: D - 30.05.2011>> | 2A/646 | 1 | |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 RelayFuel pump relay location/code no.: D - 30.05.2011>> CGGA BSE,BSF,CMXA CFHF,CLCA CFHC,CLCB CEGA CAXA | | RelayFuel pump relay location/code no.: D - 30.05.2011>> | 2B/646 | 1 | CGGA BSE,BSF,CMXA CFHF,CLCA CFHC,CLCB CEGA CAXA |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: to be used for code no.: D - 31.05.2010>> PR:9M1,9M9 | | Relay relay location/code no.: to be used for code no.: D - 31.05.2010>> | 3A/646 /449 | 1 | PR:9M1,9M9 |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: to be used for code no.: D - 31.05.2010>> CAYC BJB,BXE,BLS CHWA AZV,BKD,BMM CEGA CLCA,CLCB PR:9M1,9M9 | | Relay relay location/code no.: to be used for code no.: D - 31.05.2010>> | 3B/646 /449 | 1 | CAYC BJB,BXE,BLS CHWA AZV,BKD,BMM CEGA CLCA,CLCB PR:9M1,9M9 |
| | (10) | 4H0 951 253 | 4H0 951 253 qty: 1 Relay relay location/code no.: to be used for code no.: D - 31.05.2010>> | | Relay relay location/code no.: to be used for code no.: D - 31.05.2010>> | 2nd stage 3/644 /370 | 1 | |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 RelaySignal horn relay location/code no.: to be used for code no.: D - 31.05.2010>> - 29.05.2011 | | RelaySignal horn relay location/code no.: to be used for code no.: D - 31.05.2010>> - 29.05.2011 | 4A/646 /449 | 1 | |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: D - 31.05.2010>> - 29.05.2011 CGGA BSE,BSF,CMXA CMXA CEGA | | Relay relay location/code no.: D - 31.05.2010>> - 29.05.2011 | 4B/646 | 1 | CGGA BSE,BSF,CMXA CMXA CEGA |
| | (10) | 7N0 951 253 | 7N0 951 253 qty: 1 Relay relay location/code no.: D - 30.05.2011>> PR:7L6 | | Relay relay location/code no.: D - 30.05.2011>> | 4/507 | 1 | PR:7L6 |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: D - 31.05.2010>> PR:8X1 | | Relay relay location/code no.: D - 31.05.2010>> | 5A/646 | 1 | PR:8X1 |
| | (10A) | 4H0 951 253 C | 4H0 951 253 C qty: 1 Relay relay location/code no.: D - 31.05.2010>> | | Relay relay location/code no.: D - 31.05.2010>> | 5B/646 | 1 | |
| | 11 | N01 713 116 | N01 713 116 qty: X flat fuse 19/2x5 Slot: | | flat fuse 19/2x5 Slot: | 5A -lt brown- 5 | X | |
| | 11 | 443 937 105 A | 443 937 105 A qty: 1 Thermal fuseControl unit for memory seatand backrest adjustment | | Thermal fuseControl unit for memory seatand backrest adjustment | 30A | 1 | |
| | 15 | 1K1 941 397 G | 1K1 941 397 G qty: 1 Bracket | | Bracket | lhd | 1 | |
| | (15) | 1K2 941 397 C | 1K2 941 397 C qty: 1 Bracket | | Bracket | rhd | 1 | |
| | 16 | N10 009 110 | N10 009 110 qty: 4 hexagon head bolt (combi) | | hexagon head bolt (combi) | M6X12 | 4 | |
| | 17 | N90 327 506 | N90 327 506 qty: 1 Speed nut | | Speed nut | M6X23, 5X14, 2 | 1 | |
| | | | fuse holder | | fuse holder | | | |
| | 20 | 1K1 941 824 | 1K1 941 824 qty: 1 fuse holder | | fuse holder | lhd | 1 | |
| | (20) | 1K2 941 824 | 1K2 941 824 qty: 1 fuse holder | | fuse holder | rhd | 1 | |
| | 21 | N01 713 111 | N01 713 111 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 10A -red- | X | |
| | (21) | N01 713 112 | N01 713 112 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 15A -lt blue- | X | |
| | (21) | N01 713 113 | N01 713 113 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 20A -yellow- | X | |
| | (21) | N01 713 114 | N01 713 114 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 25A -cl.glass- | X | |
| | (21) | N01 713 115 | N01 713 115 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 30A-lt green- | X | |
| | (21) | N01 713 116 | N01 713 116 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 5A -lt brown- | X | |
| | (21) | N01 713 117 | N01 713 117 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 3A -violet- | X | |
| | (21) | N01 713 118 | N01 713 118 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 7.5A -brown- | X | |
| | (21) | N01 713 119 | N01 713 119 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 1A -black- | X | |
| | (21) | N01 713 120 | N01 713 120 qty: X flat fuse 19/2x5 | | flat fuse 19/2x5 | 40A -orange- | X | |
| | (21) | 8L0 998 131 | 8L0 998 131 qty: X 1 set of flat fuses | | 1 set of flat fuses | | X | |
| | 22 | N10 261 501 | N10 261 501 qty: X flat fuse 10/2x2, 8 | | flat fuse 10/2x2, 8 | 5A -lt brown- | X | |
| | (22) | N10 261 502 | N10 261 502 qty: X flat fuse 10/2x2, 8 | | flat fuse 10/2x2, 8 | 7.5A -brown- | X | |
| | (22) | N10 261 503 | N10 261 503 qty: X flat fuse 10/2x2, 8 | | flat fuse 10/2x2, 8 | 10A -red- | X | |
| | (22) | N10 261 507 | N10 261 507 qty: X flat fuse 10/2x2, 8 | | flat fuse 10/2x2, 8 | 15A -lt blue- | X | |
| | (22) | N10 261 508 | N10 261 508 qty: X flat fuse 10/2x2, 8 | | flat fuse 10/2x2, 8 | 20A -yellow- | X | |
| | 23 | 8D0 941 802 | 8D0 941 802 qty: 1 Assembly tool for bladefuse | | Assembly tool for bladefuse | | 1 | |
| | 24 | N90 917 104 | N90 917 104 qty: 4 Hex socket oval head collared | | Hex socket oval head collared | M5X25 | 4 | |
| | 25 | | qty: 1 sticker for fuselay-out see illustration: | | sticker for fuselay-out see illustration: | 011-020 | 1 | |
| | 30 | 3C0 937 524 E | 3C0 937 524 E qty: 1 Jumperterminal for wire cross section: | | Jumperterminal for wire cross section: | 3 point 75 6 | 1 | |
| | (30) | 1K0 937 524 B | 1K0 937 524 B qty: 1 Jumperterminal for wire cross section: | | Jumperterminal for wire cross section: | 3 point 15 4 | 1 | |
| | 31 | 3C0 937 524 L | 3C0 937 524 L qty: 1 Jumperterminal for wire cross section: | | Jumperterminal for wire cross section: | 5 point 15 4 | 1 | |
| | 32 | 1K0 937 524 | 1K0 937 524 qty: 1 Jumperterminal for wire cross section: | | Jumperterminal for wire cross section: | 6-pin 30 6 | 1 | |
| | 32 | 1K0 937 524 E | 1K0 937 524 E qty: 1 Jumperterminal for wire cross section: | | Jumperterminal for wire cross section: | 6-pin 15 4 | 1 | |
| | 35 | 1K0 937 702 D | 1K0 937 702 D qty: 1 || || || || || X || X || X || X || X || X || X || X || X Flat contact housing withcontact locking mechanismConnection pieceOnboard supply control unit Slot:Single wire | | Flat contact housing withcontact locking mechanismConnection pieceOnboard supply control unit Slot:Single wire | 52 pin A 000 979 009 E 000 979 009 EA 000 979 025 E 000 979 025 EA 000 979 026 E 000 979 026 EA 000 979 027 E 000 979 243 E 000 979 308 E | 1 || || || || || X || X || X || X || X || X || X || X || X | |
| | 36 | 1K0 937 702 E | 1K0 937 702 E qty: 1 || || || || || X || X || X || X || X || X || X || X || X Flat contact housing withcontact locking mechanismConnection pieceOnboard supply control unit Slot:Single wire | | Flat contact housing withcontact locking mechanismConnection pieceOnboard supply control unit Slot:Single wire | 52 pin B 000 979 009 E 000 979 009 EA 000 979 025 E 000 979 025 EA 000 979 026 000 979 026 EA 000 979 027 E 000 979 243 E 000 979 308 E | 1 || || || || || X || X || X || X || X || X || X || X || X | |
| | 37 | 1K0 937 702 F | 1K0 937 702 F qty: 1 || || || || || X || X || X || X || X || X || X || X || X Flat contact housing withcontact locking mechanismConnection pieceOnboard supply control unit Slot:Single wire | | Flat contact housing withcontact locking mechanismConnection pieceOnboard supply control unit Slot:Single wire | 52 pin C 000 979 009 E 000 979 009 EA 000 979 025 E 000 979 025 EA 000 979 026 000 979 026 EA 000 979 027 E 000 979 243 E 000 979 308 E | 1 || || || || || X || X || X || X || X || X || X || X || X | |
| | 40 | 8E0 972 420 | 8E0 972 420 qty: 1 || || || || X || X Flat contact housing withcontact locking mechanismDiagnosis interface fordata bus (Gateway) Possible single wire: 0,5 0,75 | | Flat contact housing withcontact locking mechanismDiagnosis interface fordata bus (Gateway) Possible single wire: | 20 pin red 000 979 009 E 000 979 164 E | 1 || || || || X || X | 0,5 0,75 |