| | | | Control unit (BCM) forconvenience system, Gatewayand onboard power supply | | Control unit (BCM) forconvenience system, Gatewayand onboard power supply | | | |
| | | | Control unit (BCM) forconv. system & OB power supply D - 09.12.2019>> - 31.08.2020 PR:GP1+7ZY | | Control unit (BCM) forconv. system & OB power supply D - 09.12.2019>> - 31.08.2020 | | | PR:GP1+7ZY |
| | 1 | 2Q0 937 089 B | 2Q0 937 089 B qty: 1 Control unit (BCM) forconvenience system, Gatewayand onboard power supply PR:GP1+1MA, 1MD,1MM,2ZA | | Control unit (BCM) forconvenience system, Gatewayand onboard power supply | 433MHZ | 1 | PR:GP1+1MA, 1MD,1MM,2ZA |
| | (1) | 2Q0 937 089 B | 2Q0 937 089 B qty: 1 Control unit (BCM) forconvenience system, Gatewayand onboard power supply also to be used for: PR:GP0 | | Control unit (BCM) forconvenience system, Gatewayand onboard power supply also to be used for: | 433MHZ 2Q0 937 087 A 2Q0 937 085 A | 1 | PR:GP0 |
| | (1) | 2Q0 937 090 B | 2Q0 937 090 B qty: 1 Control unit (BCM) forconv. system & OB power supply PR:GP1+2FM, 2ZX | | Control unit (BCM) forconv. system & OB power supply | 433MHZ | 1 | PR:GP1+2FM, 2ZX |
| | | | Control unit (BCM) forconv. system & OB power supply D - 31.08.2020>> - 05.07.2021 PR:GP1+7ZY | | Control unit (BCM) forconv. system & OB power supply D - 31.08.2020>> - 05.07.2021 | | | PR:GP1+7ZY |
| | 1 | 2Q0 937 089 C | 2Q0 937 089 C qty: 1 Control unit (BCM) forconvenience system, Gatewayand onboard power supply PR:GP1+1MA, 1MD,1MM,2ZA | | Control unit (BCM) forconvenience system, Gatewayand onboard power supply | 433MHZ | 1 | PR:GP1+1MA, 1MD,1MM,2ZA |
| | (1) | 2Q0 937 090 C | 2Q0 937 090 C qty: 1 Control unit (BCM) forconv. system & OB power supply PR:GP1+2FM, 2ZX | | Control unit (BCM) forconv. system & OB power supply | 433MHZ | 1 | PR:GP1+2FM, 2ZX |
| | | | Control unit (BCM) forconv. system & OB power supply D - 05.07.2021>> - 31.03.2022 PR:7ZY | | Control unit (BCM) forconv. system & OB power supply D - 05.07.2021>> - 31.03.2022 | | | PR:7ZY |
| | 1 | 2Q0 937 089 D | 2Q0 937 089 D qty: 1 Control unit (BCM) forconvenience system, Gatewayand onboard power supply PR:1MA,1MD, 1MM,2ZA | | Control unit (BCM) forconvenience system, Gatewayand onboard power supply | 433MHZ | 1 | PR:1MA,1MD, 1MM,2ZA |
| | (1) | 2Q0 937 090 D | 2Q0 937 090 D qty: 1 Control unit (BCM) forconv. system & OB power supply PR:2FM,2ZX | | Control unit (BCM) forconv. system & OB power supply | | 1 | PR:2FM,2ZX |
| | | | Diagnosis interface fordata bus (Gateway) D - 09.12.2019>> - 31.08.2020 PR:2FM,2ZX+ 7ZY | | Diagnosis interface fordata bus (Gateway) D - 09.12.2019>> - 31.08.2020 | | | PR:2FM,2ZX+ 7ZY |
| | 2 | 3Q0 907 530 A C | 3Q0 907 530 A C qty: 1 Diagnosis interface fordata bus (Gateway) | | Diagnosis interface fordata bus (Gateway) | | 1 | |
| | | | Diagnosis interface fordata bus (Gateway) D - 31.08.2020>> - 05.07.2021 PR:2FM,2ZX+ 7ZY | | Diagnosis interface fordata bus (Gateway) D - 31.08.2020>> - 05.07.2021 | | | PR:2FM,2ZX+ 7ZY |
| | 2 | 3Q0 907 530 A G | 3Q0 907 530 A G qty: 1 Diagnosis interface fordata bus (Gateway) PR:2FM,2ZX+ 7ZY | | Diagnosis interface fordata bus (Gateway) | | 1 | PR:2FM,2ZX+ 7ZY |
| | | | Diagnosis interface fordata bus (Gateway) D - 05.07.2021>> PR:2FM,2ZX+ 7ZY | | Diagnosis interface fordata bus (Gateway) D - 05.07.2021>> | | | PR:2FM,2ZX+ 7ZY |
| | 2 | 3Q0 907 530 A L | 3Q0 907 530 A L qty: 1 Diagnosis interface fordata bus (Gateway) PR:2FM,2ZX+ 7ZY | | Diagnosis interface fordata bus (Gateway) | | 1 | PR:2FM,2ZX+ 7ZY |
| | | | Control unit for corneringlight and headlight range ctrl D - 09.12.2019>> PR:7ZY+8IX+ 8Q3 | | Control unit for corneringlight and headlight range ctrl D - 09.12.2019>> | | | PR:7ZY+8IX+ 8Q3 |
| | 3 | 7P6 907 357 E | 7P6 907 357 E qty: 1 Control unit for corneringlight and headlight range ctrl | | Control unit for corneringlight and headlight range ctrl | | 1 | |
| | | | Control unit for access andstart authorisation D - 09.12.2019>> PR:7ZY | | Control unit for access andstart authorisation D - 09.12.2019>> | | | PR:7ZY |
| | 4 | | Control unit for access andstart authorisation PR:4F2,4I3+ 7ZY | | Control unit for access andstart authorisation | | | PR:4F2,4I3+ 7ZY |
| | | | Fasteners D - 09.12.2019>> PR:7ZY | | Fasteners D - 09.12.2019>> | | | PR:7ZY |
| | 5 | 6C0 907 371 A | 6C0 907 371 A qty: 1 Retainer for control unit | | Retainer for control unit | 'BCM' | 1 | |
| | 6 | 6RA 971 303 | 6RA 971 303 qty: 1 Bracket for data busdiagnostic interface (gateway)and/or contr. units for accessand start authorisationDiagnosis interface fordata bus (Gateway)Control unit for access andstart authorisation | | Bracket for data busdiagnostic interface (gateway)and/or contr. units for accessand start authorisationDiagnosis interface fordata bus (Gateway)Control unit for access andstart authorisation | | 1 | |
| | 7 | 6JB 971 845 | 6JB 971 845 qty: 1 Bracket for control unitfor cornering light andheadlight range controlControl unit for corneringlight and headlight range ctrl | | Bracket for control unitfor cornering light andheadlight range controlControl unit for corneringlight and headlight range ctrl | | 1 | |
| | 8 | N90 698 601 | N90 698 601 qty: 1 Hexagon socket head panel bolt see drawing: | | Hexagon socket head panel bolt see drawing: | ST4, 2X16 N 906 986 | 1 | |