Individual parts - Yeti(YET) [EUROPA 2011 year]

Individual parts  - Yeti - yet
part number information description remark unit model
Wiring set for air-conditioning actuation
Wiring set for air-conditioning actuation
Wiring set for air-conditioning actuation
Wiring set for air-conditioning actuation
1   5K1 971 566    5K1 971 566 qty: 1
Wiring set for air-conditioning actuation
  Wiring set for air-conditioning actuation lhd 1
1   5K2 971 566    5K2 971 566 qty: 1
Wiring set for air-conditioning actuation
  Wiring set for air-conditioning actuation rhd 1
2   1K1 971 566 A N   1K1 971 566 A N qty: 1
Wiring set for electronicallyregulated air-conditioning
  Wiring set for electronicallyregulated air-conditioning lhd 1
2   1K2 971 566 A N   1K2 971 566 A N qty: 1
Wiring set for electronicallyregulated air-conditioning
  Wiring set for electronicallyregulated air-conditioning rhd 1
-   5K1 971 566 B    5K1 971 566 B qty: 1
Wiring set for air-conditioning actuation
DENSO
  Wiring set for air-conditioning actuation lhd 1 DENSO
-   5K1 971 566 N    5K1 971 566 N qty: 1
Wiring set for air-conditioning actuation
DENSO
  Wiring set for air-conditioning actuation lhd 1 DENSO
Individual parts
Individual parts
5   1J0 937 713 A    1J0 937 713 A qty: 1 || || 1
Flat contact housing withcontact locking mechanism use if required:Fan motorfor vehicles with electroni-cally regulated air condit. Possible single wire:
  Flat contact housing withcontact locking mechanism use if required:Fan motorfor vehicles with electroni-cally regulated air condit. Possible single wire: 3 pin
brown
1J0 937 714 A 000 979 133 000 979 135 E 000 979 225 E 000 979 227 E
1 || || 1
(5)   1J0 937 714 A    1J0 937 714 A qty: 1 || || 1
Flat contact housing withcontact locking mechanism use if required:Fan motorfor vehicles with electroni-cally regulated air condit. Possible single wire:
  Flat contact housing withcontact locking mechanism use if required:Fan motorfor vehicles with electroni-cally regulated air condit. Possible single wire: 3 pin
brown
1J0 937 713 A 000 979 133 000 979 135 E 000 979 225 E 000 979 227 E
1 || || 1
7   3D0 971 497 D    3D0 971 497 D qty: 1
cable tie with terminal socket
  cable tie with terminal socket 1
8   8L0 971 838    8L0 971 838 qty: X
Cable tie with holder for plastic pin:
  Cable tie with holder for plastic pin: 5X300 5 X
9   1J0 971 972    1J0 971 972 qty: 1
flat connector housingTemperature sensor Possible single wire:
  flat connector housingTemperature sensor Possible single wire: 2 pin
000 979 131 E 000 979 131 EA
1
10   1J0 972 923    1J0 972 923 qty: 1
Flat contact housing withcontact locking mechanismTemperature sensor Possible single wire:
  Flat contact housing withcontact locking mechanismTemperature sensor Possible single wire: 2 pin
000 979 133 000 979 133 EA
1
10A   1K0 972 704    1K0 972 704 qty: 1
Flat contact housingfor vehicles with additionalelectric air heater Possible single wire:
  Flat contact housingfor vehicles with additionalelectric air heater Possible single wire: 4 pin
black
000 979 009 E 000 979 009 EA
1
11   6Q0 972 706    6Q0 972 706 qty: X || || || 1 || || 2 || 1
Flat contact housing withcontact locking mechanismControl flapfor recirculated air operationpossibilityControl flapDefroster flap Possible single wire:
  Flat contact housing withcontact locking mechanismControl flapfor recirculated air operationpossibilityControl flapDefroster flap Possible single wire: 6 pin
blue
000 979 009 E 000 979 009 EA
X || || || 1 || || 2 || 1
12   1J0 972 752    1J0 972 752 qty: 1
Flat contact housingFan motor Possible single wire:
  Flat contact housingFan motor Possible single wire: 2 pin
000 979 133 000 979 133 EA 000 979 225 E
1
13   1J0 972 754    1J0 972 754 qty: 1
Flat contact housingseries resistance for freshair and hot air blower Possible single wire:
  Flat contact housingseries resistance for freshair and hot air blower Possible single wire: 4 pin
000 979 135 E 000 979 227 E
1
14   1J0 972 755    1J0 972 755 qty: 1
Flat contact housingDisplay and control panel withcontrol unit for manuallycontrolled air conditioning Possible single wire:
  Flat contact housingDisplay and control panel withcontrol unit for manuallycontrolled air conditioning Possible single wire: 5 pin
000 979 306
1
15   1J0 972 785    1J0 972 785 qty: 1
Flat contact housing withcontact locking mechanismCoupling elementwiring harness for interior Possible single wire:
  Flat contact housing withcontact locking mechanismCoupling elementwiring harness for interior Possible single wire: 10 pin
000 979 136 E 000 979 228 E
1
16   1K0 972 928    1K0 972 928 qty: X || || || || 1 || || || 1
Flat contact housing withcontact locking mechanismDisplay and control panel withcontrol unit for manuallycontrolled air conditioningControl and display panelfor air-conditioning systemClimatronic Possible single wire:
  Flat contact housing withcontact locking mechanismDisplay and control panel withcontrol unit for manuallycontrolled air conditioningControl and display panelfor air-conditioning systemClimatronic Possible single wire: 16 pin
black
000 979 009 E
X || || || || 1 || || || 1
17   1K0 972 928 A    1K0 972 928 A qty: 1 || X
Flat contact housingControl and display panelfor air-conditioning systemClimatronic Possible single wire:
  Flat contact housingControl and display panelfor air-conditioning systemClimatronic Possible single wire: 16 pin
brown
000 979 009 E
1 || X
18   6Q0 971 838 C    6Q0 971 838 C qty: X
Cable tie with holder for weld pin:
  Cable tie with holder for weld pin: 5X200 5 X