| | | | Central wiring set area:wiring harness: front left | | Central wiring set area:wiring harness: front left | | | |
| | | | Individual parts area:wiring harness: front left | | Individual parts area:wiring harness: front left | | | |
| | - | | Direction of travel | | Direction of travel | | | |
| | - | 1S0 973 038 | 1S0 973 038 qty: 1 Flat contact housingControl unit for ABS | | Flat contact housingControl unit for ABS | | 1 | |
| | - | 1K0 973 038 | 1K0 973 038 qty: 1 flat contact housing withgasket Possible single wire:slide valveBracket for ESP sensor unit | | flat contact housing withgasket Possible single wire:slide valveBracket for ESP sensor unit | 38 pin right right | 1 | |
| | - | 000 979 026 | 000 979 026 qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 0, 5 2, 8 | X | |
| | - | 000 979 243 | 000 979 243 qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 2, 5 4, 8 | X | |
| | - | 5Q0 972 752 | 5Q0 972 752 qty: 1 Flat contact housingfuse holder | | Flat contact housingfuse holder | 2 pinblack | 1 | |
| | - | 5Q0 972 718 | 5Q0 972 718 qty: 1 Flat contact housing withcontact locking mechanism cable output:Control unit for parking aid | | Flat contact housing withcontact locking mechanism cable output:Control unit for parking aid | 18 pinblackside | 1 | |
| | - | 5Q0 937 702 | 5Q0 937 702 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | 46-pinBlack/ black | 1 | |
| | - | 4F0 972 575 A | 4F0 972 575 A qty: 1 Flat connector housing withcontact locking mechanism also to be used for: counterpart to: | | Flat connector housing withcontact locking mechanism also to be used for: counterpart to: | 17-pin brown green violet 4F0 972 483 A | 1 | |
| | - | 4F0 972 483 A | 4F0 972 483 A qty: X Flat contact housing withcontact locking mechanism also to be used for: | | Flat contact housing withcontact locking mechanism also to be used for: | 17-pinbrowngreenviolet | X | |
| | - | 4F0 972 575 B | 4F0 972 575 B qty: 1 Flat connector housing withcontact locking mechanism also to be used for: counterpart to: | | Flat connector housing withcontact locking mechanism also to be used for: counterpart to: | 17-pin red Grey light-green 4F0 972 483 B | 1 | |
| | - | 4F0 972 483 B | 4F0 972 483 B qty: X Flat contact housing withcontact locking mechanism also to be used for: | | Flat contact housing withcontact locking mechanism also to be used for: | 17-pinredGreylight-green | X | |
| | - | 4F0 972 575 D | 4F0 972 575 D qty: 1 Flat connector housing withcontact locking mechanism also to be used for: counterpart to: | | Flat connector housing withcontact locking mechanism also to be used for: counterpart to: | 17-pin blue orange light pink 4F0 972 483 D | 1 | |
| | - | 4F0 972 483 D | 4F0 972 483 D qty: X Flat contact housing withcontact locking mechanism also to be used for: | | Flat contact housing withcontact locking mechanism also to be used for: | 17-pinblueorangelight pink | X | |
| | - | 4F0 972 575 | 4F0 972 575 qty: 1 Flat connector housing withcontact locking mechanism also to be used for: counterpart to: | | Flat connector housing withcontact locking mechanism also to be used for: counterpart to: | 17-pin black white dark brown khaki grey 4F0 972 483 | 1 | |
| | - | 4F0 972 483 | 4F0 972 483 qty: X Flat contact housing withcontact locking mechanism also to be used for: | | Flat contact housing withcontact locking mechanism also to be used for: | 17-pinblackwhitedark brownkhaki grey | X | |
| | - | 4F0 972 575 A | 4F0 972 575 A qty: 1 Flat connector housing withcontact locking mechanism also to be used for: counterpart to: | | Flat connector housing withcontact locking mechanism also to be used for: counterpart to: | 17-pin brown green violet 4F0 972 483 A | 1 | |
| | - | 7M3 972 726 B | 7M3 972 726 B qty: 1 flat contact housing withcapLocking mechanism Possible single wire:Control unit for corneringlight and headlight range ctrl | | flat contact housing withcapLocking mechanism Possible single wire:Control unit for corneringlight and headlight range ctrl | 26 pin white black 000 979 009 E 000 979 009 EA | 1 | |
| | - | 8R0 973 605 | 8R0 973 605 qty: 1 Flat contact housing Possible single wire: matching contact housing:Clutch position sender | | Flat contact housing Possible single wire: matching contact housing:Clutch position sender | 5 pin black 000 979 009 E 000 979 009 EA 8R0 973 705 | 1 | |
| | - | 8R0 973 705 | 8R0 973 705 qty: 1 Flat contact housing | | Flat contact housing | 5 pinblack | 1 | |
| | - | 8K0 973 706 | 8K0 973 706 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire:Accelerator pedal | | Flat contact housing withcontact locking mechanism Possible single wire:Accelerator pedal | 6 pin black 000 979 025 | 1 | |
| | - | 000 979 025 | 000 979 025 qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 0, 5 1, 5 | X | |
| | - | 7M3 972 726 B | 7M3 972 726 B qty: 1 flat contact housing withcapLocking mechanism Possible single wire:Control unit for corneringlight and headlight range ctrl | | flat contact housing withcapLocking mechanism Possible single wire:Control unit for corneringlight and headlight range ctrl | 26 pin white black 000 979 009 E 000 979 009 EA | 1 | |
| | - | 000 979 009 E | 000 979 009 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat connector/sleeve withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat connector/sleeve withretaining lug | 0, 5 -40C/+125C 0, 63 | X | |
| | - | 000 979 009 E A | 000 979 009 E A qty: 1 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' with cable crosssection:flat connector/sleeve withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' with cable crosssection:flat connector/sleeve withretaining lug | -40C/+125C 0, 5 0, 63 | 1 | |
| | - | 5Q0 972 718 | 5Q0 972 718 qty: 1 Flat contact housing withcontact locking mechanism cable output:Control unit for parking aid | | Flat contact housing withcontact locking mechanism cable output:Control unit for parking aid | 18 pinblackside | 1 | |
| | - | 8K0 973 702 | 8K0 973 702 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing: 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing: | 2 pin black 000 979 025 E 000 979 025 EA 000 979 150 E 000 979 150 EA 1J0 973 802 | 1 | 0,5 0,5 1,0 1,0 |
| | - | 000 979 025 E | 000 979 025 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 0, 5 -40C/+125C 1, 5 | X | |
| | - | 000 979 025 E A | 000 979 025 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' with cable crosssection:flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' with cable crosssection:flat contact withretaining lug | -40C/+125C 0, 5QMM 1, 5MM | X | |
| | - | 000 979 150 E | 000 979 150 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 1, 0 -40C/+125C 1, 5 | X | |
| | - | 000 979 150 E A | 000 979 150 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 1, 0 -40C/+125C 1, 5 | X | |
| | - | 1J0 973 802 | 1J0 973 802 qty: 1 Flat connector housing withcontact locking mechanism | | Flat connector housing withcontact locking mechanism | 2 pin | 1 | |
| | - | 4H0 973 712 | 4H0 973 712 qty: 1 Flat contact housing withcontact locking mechanismswitch - brake light | | Flat contact housing withcontact locking mechanismswitch - brake light | | 1 | |
| | - | 4H0 973 713 | 4H0 973 713 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | | 1 | |
| | - | 4H0 973 715 | 4H0 973 715 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | | 1 | |
| | - | 4F0 973 703 | 4F0 973 703 qty: 1 Flat contact housing withcontact locking mechanismsensor for brakeservo 0,5 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanismsensor for brakeservo | 3 pin black 000 979 034 E 000 979 034 EA 000 979 034 EC 000 979 159 EA 000 979 159 EC | 1 | 0,5 0,5 0,5 1,0 1,0 |
| | - | 000 979 034 E | 000 979 034 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5' with cable crosssection:flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5' with cable crosssection:flat contact withretaining lug | -40C/+125C 0, 5QMM 1, 2MM | X | |
| | - | 000 979 034 E A | 000 979 034 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' with cable crosssection:flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' with cable crosssection:flat contact withretaining lug | -40C/+125C 0, 5QMM 1, 2MM | X | |
| | - | 000 979 034 E C | 000 979 034 E C qty: X 1 set single wires each with2 silver-plated contacts, in bag of 5'Order quantity. 5' with cable crosssection:flat contact withretaining lug | | 1 set single wires each with2 silver-plated contacts, in bag of 5'Order quantity. 5' with cable crosssection:flat contact withretaining lug | -40C/+125C 0, 5QMM 1, 2MM | X | |
| | - | 000 979 159 E A | 000 979 159 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' | | X | |
| | - | 000 979 159 E C | 000 979 159 E C qty: X 1 set single wires each with2 silver-plated contacts, in bag of 5'Order quantity. 5' with cable crosssection:flat contact withretaining lug | | 1 set single wires each with2 silver-plated contacts, in bag of 5'Order quantity. 5' with cable crosssection:flat contact withretaining lug | -40C/+125C 1, 0QMM 1, 2MM | X | |
| | - | 4B0 973 724 | 4B0 973 724 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing: 0,5 1,0 2,5 | | Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing: | 4 pin black 000 979 026 EA 000 979 151 EA 000 979 242 EA 1J0 973 824 | 1 | 0,5 1,0 2,5 |
| | - | 000 979 026 E A | 000 979 026 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 0, 5 -40C/+125C 2, 8 | X | |
| | - | 000 979 151 E A | 000 979 151 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 1, 0 -40C/+125C 2, 8 | X | |
| | - | 000 979 242 E A | 000 979 242 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' | | X | |
| | - | 1J0 973 824 | 1J0 973 824 qty: 1 Flat contact housing | | Flat contact housing | 4 pinblack | 1 | |
| | - | 8K0 973 704 | 8K0 973 704 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:Lambda probe(behind catalyst) 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:Lambda probe(behind catalyst) | 4 pin black 000 979 025 E 000 979 025 EA 000 979 150 E 000 979 150 EA 1K0 973 804 | 1 | 0,5 0,5 1,0 1,0 |
| | - | 1K0 973 804 | 1K0 973 804 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | 4 pinblack | 1 | |
| | - | 8K0 973 704 A | 8K0 973 704 A qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:Lambda probe(in front of catalyst) 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:Lambda probe(in front of catalyst) | 4 pin brown 000 979 025 E 000 979 025 EA 000 979 150 E 000 979 150 EA 1K0 973 804 A | 1 | 0,5 0,5 1,0 1,0 |
| | - | 1K0 973 804 A | 1K0 973 804 A qty: X Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | 4 pindark brown | X | |
| | - | 8K0 973 705 | 8K0 973 705 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:Lambda probe(in front of catalyst) 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:Lambda probe(in front of catalyst) | 5 pin black 000 979 025 E 000 979 025 EA 000 979 150 E 000 979 150 EA 6N0 973 805 | 1 | 0,5 0,5 1,0 1,0 |
| | - | 000 979 025 E | 000 979 025 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 0, 5 -40C/+125C 1, 5 | X | |
| | - | 000 979 025 E A | 000 979 025 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' with cable crosssection:flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' with cable crosssection:flat contact withretaining lug | -40C/+125C 0, 5QMM 1, 5MM | X | |
| | - | 000 979 150 E | 000 979 150 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 1, 0 -40C/+125C 1, 5 | X | |
| | - | 000 979 150 E A | 000 979 150 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 1, 0 -40C/+125C 1, 5 | X | |
| | - | 6N0 973 805 | 6N0 973 805 qty: 1 Flat contact housing | | Flat contact housing | 5 pinblack | 1 | |
| | - | 8K0 973 704 | 8K0 973 704 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:Lambda probe(behind catalyst) 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:Lambda probe(behind catalyst) | 4 pin black 000 979 025 E 000 979 025 EA 000 979 150 E 000 979 150 EA 1K0 973 804 | 1 | 0,5 0,5 1,0 1,0 |
| | - | 1K0 973 804 | 1K0 973 804 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | 4 pinblack | 1 | |
| | - | 5Q0 937 125 B | 5Q0 937 125 B qty: 1 E boxfuse holder | | E boxfuse holder | | 1 | |
| | - | 1J0 973 735 | 1J0 973 735 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire:Headlights | | Flat contact housing withcontact locking mechanism Possible single wire:Headlights | 10 pin black 000 979 131 000 979 133 000 979 133 A 000 979 225 000 979 225 A | 1 | |
| | - | 000 979 131 | 000 979 131 qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | 1, 0 1, 5 | X | |
| | - | 000 979 133 | 000 979 133 qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | 1, 0 2, 8 | X | |
| | - | 000 979 133 A | 000 979 133 A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | 1, 0 2, 8 | X | |
| | - | 000 979 225 | 000 979 225 qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5' | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5' | | X | |
| | - | 000 979 225 A | 000 979 225 A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | 2, 5 2, 8 | X | |
| | - | 3C0 973 737 | 3C0 973 737 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire:Headlights 0,5 0,5 1,0 1,0 2,5 | | Flat contact housing withcontact locking mechanism Possible single wire:Headlights | 14 pin 000 979 025 A 000 979 026 A 000 979 150 A 000 979 151 A 000 979 242 A | 1 | 0,5 0,5 1,0 1,0 2,5 |
| | - | 000 979 025 A | 000 979 025 A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 0, 5 1, 5 | X | |
| | - | 000 979 026 A | 000 979 026 A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 0, 5 2, 8 | X | |
| | - | 000 979 150 A | 000 979 150 A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 1, 0 1, 5 | X | |
| | - | 000 979 151 A | 000 979 151 A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 1, 0 1, 5 | X | |
| | - | 000 979 242 A | 000 979 242 A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 2, 5 2, 8 | X | |
| | - | 8P0 973 722 | 8P0 973 722 qty: 1 Flat contact housing withcontact locking mechanismWindscreen washer system pump | | Flat contact housing withcontact locking mechanismWindscreen washer system pump | | 1 | |
| | - | 1K0 973 202 | 1K0 973 202 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire:water level sender | | Flat contact housing withcontact locking mechanism Possible single wire:water level sender | 2 pin black 000 979 133 E 000 979 133 EA 000 979 225 E 000 979 225 EA | 1 | |
| | - | 000 979 133 E | 000 979 133 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5' | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5' | | X | |
| | - | 000 979 133 E A | 000 979 133 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | 1, 0 -40C/+125C 2, 8 | X | |
| | - | 000 979 225 E | 000 979 225 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | 2, 5 -40C/+125C 2, 8 | X | |
| | - | 000 979 225 E A | 000 979 225 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' | | X | |
| | - | 1J0 973 722 A | 1J0 973 722 A qty: 1 Flat contact housing withcontact locking mechanism Possible single wire:Injector unit for headlightcleaning | | Flat contact housing withcontact locking mechanism Possible single wire:Injector unit for headlightcleaning | 2 pin black 000 979 133 E 000 979 133 EA 000 979 225 E 000 979 225 EA | 1 | |
| | - | 000 979 133 E | 000 979 133 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5' | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5' | | X | |
| | - | 000 979 133 E A | 000 979 133 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | 1, 0 -40C/+125C 2, 8 | X | |
| | - | 000 979 225 E | 000 979 225 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | 2, 5 -40C/+125C 2, 8 | X | |
| | - | 000 979 225 E A | 000 979 225 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' | | X | |
| | - | 1J0 906 380 B | 1J0 906 380 B qty: 1 flat contact housing withgasketControl unit Possible single wire:Control unit for automaticgearbox | | flat contact housing withgasketControl unit Possible single wire:Control unit for automaticgearbox | 52 POLIG 000 979 131 E 000 979 131 EA | 1 | |
| | - | 000 979 131 E | 000 979 131 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | 1, 0 -40C/+125C 1, 5 | X | |
| | - | 000 979 131 E A | 000 979 131 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | 1, 0 -40C/+125C 1, 5 | X | |
| | - | 5Q0 906 385 | 5Q0 906 385 qty: 1 Flat contact housing withcontact locking mechanism cable output:Engine control unit | | Flat contact housing withcontact locking mechanism cable output:Engine control unit | 94-pin black 25 GRAD | 1 | |
| | - | 7P6 906 971 A | 7P6 906 971 A qty: 1 Flat contact housing withcontact locking mechanismEngine control unit | | Flat contact housing withcontact locking mechanismEngine control unit | 91 pinblack | 1 | |
| | - | 1K0 906 234 | 1K0 906 234 qty: 1 Flat contact housing Possible single wire:Radiator fan 2,5 6,0 | | Flat contact housing Possible single wire:Radiator fan | 4 pin 000 979 249 E 000 979 417 E | 1 | 2,5 6,0 |
| | - | 000 979 417 E | 000 979 417 E qty: X 1 set single wires each with2 contacts, in bag of 3'Order qty. 3' with cable crosssection:flat contact | | 1 set single wires each with2 contacts, in bag of 3'Order qty. 3' with cable crosssection:flat contact | 6, 0 -40C/+125C 6, 0 9, 5 | X | |
| | - | 8K0 973 702 | 8K0 973 702 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:External temperature sensor 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:External temperature sensor | 2 pin black 000 979 025 E 000 979 025 EA 000 979 150 E 000 979 150 EA 1J0 973 802 | 1 | 0,5 0,5 1,0 1,0 |
| | - | 000 979 025 E | 000 979 025 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 0, 5 -40C/+125C 1, 5 | X | |
| | - | 000 979 025 E A | 000 979 025 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' with cable crosssection:flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5' with cable crosssection:flat contact withretaining lug | -40C/+125C 0, 5QMM 1, 5MM | X | |
| | - | 000 979 150 E | 000 979 150 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 1, 0 -40C/+125C 1, 5 | X | |
| | - | 000 979 150 E A | 000 979 150 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 1, 0 -40C/+125C 1, 5 | X | |
| | - | 1J0 973 802 | 1J0 973 802 qty: 1 Flat connector housing withcontact locking mechanism | | Flat connector housing withcontact locking mechanism | 2 pin | 1 | |
| | - | 4H0 973 712 | 4H0 973 712 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | | 1 | |
| | - | 8K0 973 702 | 8K0 973 702 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:Coolant temperature sender 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:Coolant temperature sender | 2 pin black 000 979 025 E 000 979 025 EA 000 979 150 E 000 979 150 EA 1J0 973 802 | 1 | 0,5 0,5 1,0 1,0 |
| | - | 5Q0 973 837 | 5Q0 973 837 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | 14 point | 1 | |
| | - | 1J0 973 814 | 1J0 973 814 qty: 1 Flat contact housing Possible single wire: matching contact housing: 1,0 1,0 | | Flat contact housing Possible single wire: matching contact housing: | 8 pin 000 979 132 E 000 979 132 EA 1J0 973 714 | 1 | 1,0 1,0 |
| | - | 000 979 132 E | 000 979 132 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'Flat male connector withdetent lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'Flat male connector withdetent lug | 1, 0 -40C/+125C 1, 5 | X | |
| | - | 000 979 132 E A | 000 979 132 E A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'Flat male connector withdetent lug | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'Flat male connector withdetent lug | 1, 0 -40C/+125C 1, 5 | X | |
| | - | 1J0 973 714 | 1J0 973 714 qty: 1 Flat contact housing | | Flat contact housing | 8 pinblack | 1 | |
| | - | 4D0 971 992 | 4D0 971 992 qty: 1 Flat connector housing withcontact locking mechanism Possible single wire: 1,0 | | Flat connector housing withcontact locking mechanism Possible single wire: | 2 pin 000 979 141 E | 1 | 1,0 |
| | - | 000 979 141 E | 000 979 141 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | 1, 0 -40C/+125C 2, 8 | X | |
| | - | 4D0 971 992 | 4D0 971 992 qty: 1 Flat connector housing withcontact locking mechanism Possible single wire: 1,0 | | Flat connector housing withcontact locking mechanism Possible single wire: | 2 pin 000 979 141 E | 1 | 1,0 |
| | - | 5K0 973 323 | 5K0 973 323 qty: 1 Flat contact housing | | Flat contact housing | | 1 | |
| | - | 8P0 973 722 | 8P0 973 722 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | | 1 | |
| | - | 1J0 973 735 | 1J0 973 735 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: | | Flat contact housing withcontact locking mechanism Possible single wire: | 10 pin black 000 979 131 000 979 133 000 979 133 A 000 979 225 000 979 225 A | 1 | |
| | - | 000 979 131 | 000 979 131 qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | 1, 0 1, 5 | X | |
| | - | 000 979 133 | 000 979 133 qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact | 1, 0 2, 8 | X | |
| | - | 000 979 133 A | 000 979 133 A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | 1, 0 2, 8 | X | |
| | - | 000 979 225 | 000 979 225 qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5' | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5' | | X | |
| | - | 000 979 225 A | 000 979 225 A qty: X 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | | 1 set single wires each with2 gold-plated contacts, in bag of 5'Order qty. 5'flat contact | 2, 5 2, 8 | X | |
| | - | 4H0 973 715 | 4H0 973 715 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | | 1 | |
| | - | 4H0 973 714 | 4H0 973 714 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | | 1 | |
| | - | 4H0 973 714 | 4H0 973 714 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | | 1 | |
| | - | 5Q0 973 737 | 5Q0 973 737 qty: 1 Flat contact housing withcontact locking mechanism | | Flat contact housing withcontact locking mechanism | 14 pinGrey | 1 | |
| | - | 1K0 973 751 | 1K0 973 751 qty: 1 flat contact housing withgasket Possible single wire:Starter | | flat contact housing withgasket Possible single wire:Starter | 1 pin black 000 979 243 E | 1 | |
| | - | 000 979 243 E | 000 979 243 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 2, 5 -40C/+125C 4, 8 | X | |
| | - | 1J0 973 735 | 1J0 973 735 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire:Gearbox | | Flat contact housing withcontact locking mechanism Possible single wire:Gearbox | 10 pin black 000 979 131 000 979 133 000 979 133 A 000 979 225 000 979 225 A | 1 | |
| | - | 4H0 973 717 | 4H0 973 717 qty: 1 Flat contact housing withcontact locking mechanismGearbox6-speed automatic gearbox | | Flat contact housing withcontact locking mechanismGearbox6-speed automatic gearbox | 14 pin | 1 | |
| | - | 4H0 973 714 | 4H0 973 714 qty: 1 Flat contact housing withcontact locking mechanismGearbox | | Flat contact housing withcontact locking mechanismGearbox | | 1 | |
| | - | 1K0 973 751 | 1K0 973 751 qty: 1 flat contact housing withgasket Possible single wire:Starter | | flat contact housing withgasket Possible single wire:Starter | 1 pin black 000 979 243 E | 1 | |
| | - | 1K0 973 751 | 1K0 973 751 qty: 1 flat contact housing withgasket Possible single wire:Starter | | flat contact housing withgasket Possible single wire:Starter | 1 pin black 000 979 243 E | 1 | |
| | - | 8K0 973 702 | 8K0 973 702 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:switch for reversing light 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:switch for reversing light | 2 pin black 000 979 025 E 000 979 025 EA 000 979 150 E 000 979 150 EA 1J0 973 802 | 1 | 0,5 0,5 1,0 1,0 |
| | - | 1K0 973 213 | 1K0 973 213 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire:Control unit for automaticgearbox 0,5 0,5 1,0 2,5 4,0 | | Flat contact housing withcontact locking mechanism Possible single wire:Control unit for automaticgearbox | 25 pin black 000 979 025 E 000 979 027 E 000 979 152 E 000 979 243 E 000 979 308 E | 1 | 0,5 0,5 1,0 2,5 4,0 |
| | - | 000 979 025 E | 000 979 025 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 0, 5 -40C/+125C 1, 5 | X | |
| | - | 000 979 027 E | 000 979 027 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5' with cable crosssection:flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5' with cable crosssection:flat contact withretaining lug | -40C/+125C 0, 5 4, 8 | X | |
| | - | 000 979 152 E | 000 979 152 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 1, 0 -40C/+125C 4, 8 | X | |
| | - | 000 979 243 E | 000 979 243 E qty: X 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 5'Order qty. 5'flat contact withretaining lug | 2, 5 -40C/+125C 4, 8 | X | |
| | - | 000 979 308 E | 000 979 308 E qty: X 1 set single wires each with2 contacts, in bag of 4'Order qty. 4'flat contact withretaining lug | | 1 set single wires each with2 contacts, in bag of 4'Order qty. 4'flat contact withretaining lug | 4, 0 -40C/+125C 4, 8 | X | |
| | - | 8K0 973 702 | 8K0 973 702 qty: 1 Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:switch for reversing light 0,5 0,5 1,0 1,0 | | Flat contact housing withcontact locking mechanism Possible single wire: matching contact housing:switch for reversing light | 2 pin black 000 979 025 E 000 979 025 EA 000 979 150 E 000 979 150 EA 1J0 973 802 | 1 | 0,5 0,5 1,0 1,0 |
| | - | 5Q0 971 915 | 5Q0 971 915 qty: 1 Grommetharness for engine compartment | | Grommetharness for engine compartment | left | 1 | |
| | - | 3D0 971 497 D | 3D0 971 497 D qty: 1 cable tie with terminal socket | | cable tie with terminal socket | | 1 | |
| | - | 5Q0 937 545 | 5Q0 937 545 qty: X bracket for connector housing | | bracket for connector housing | 2 pointleft front | X | |
| | - | 5Q0 937 545 A | 5Q0 937 545 A qty: X bracket for connector housing | | bracket for connector housing | 4 point | X | |
| | - | 6Q0 971 838 B | 6Q0 971 838 B qty: 1 Cable tie with holder for weld pin: | | Cable tie with holder for weld pin: | | 1 | |
| | - | 1T0 971 930 C | 1T0 971 930 C qty: X Bundling clip f wiring harness | | Bundling clip f wiring harness | | X | |
| | - | 3D0 971 838 E | 3D0 971 838 E qty: X cable tie with terminal socket for sheet metal thickness: | | cable tie with terminal socket for sheet metal thickness: | 4, 6X200 1-3MM | X | |
| | - | 1T0 971 930 D | 1T0 971 930 D qty: X Bundling clip f wiring harness | | Bundling clip f wiring harness | | X | |
| | - | 1Y0 971 838 | 1Y0 971 838 qty: 1 cable tie with terminal socketCable ties | | cable tie with terminal socketCable ties | N 909 377 01 | 1 | |
| | - | 1T0 971 930 E | 1T0 971 930 E qty: 1 Bundling clip f wiring harness | | Bundling clip f wiring harness | | 1 | |
| | - | 1U0 971 848 A | 1U0 971 848 A qty: 1 Cable holder | | Cable holder | | 1 | |
| | - | 5Q0 927 165 B | 5Q0 927 165 B qty: X Closing element | | Closing element | | X | |
| | - | 5Q0 937 132 D | 5Q0 937 132 D qty: X Cover | | Cover | | X | |
| | - | 5Q0 907 361 B | 5Q0 907 361 B qty: X housing for centr. elec.system | | housing for centr. elec.system | | X | |
| | - | N01 100 632 | N01 100 632 qty: X Hexagon nut | | Hexagon nut | M6 | X | |
| | - | 5Q0 937 629 C | 5Q0 937 629 C qty: X Multi-fuse | | Multi-fuse | 400A | X | |
| | - | 5Q0 971 615 L | 5Q0 971 615 L qty: X Cable guideSide member | | Cable guideSide member | centre left | X | |
| | - | 5Q0 971 879 | 5Q0 971 879 qty: 1 Cable guide - upper part | | Cable guide - upper part | | 1 | |
| | - | 6Q0 971 838 C | 6Q0 971 838 C qty: X Cable tie with holder for weld pin: | | Cable tie with holder for weld pin: | 5X200 5 | X | |
| | - | 5Q0 971 615 P | 5Q0 971 615 P qty: X Cable guideSide member | | Cable guideSide member | left front | X | |
| | - | 5Q0 971 783 | 5Q0 971 783 qty: X Cover cap | | Cover cap | | X | |
| | - | 3D0 971 838 L | 3D0 971 838 L qty: X cable tie with terminal socket for sheet metal thickness: | | cable tie with terminal socket for sheet metal thickness: | 4, 6X200 1-3MM | X | |
| | - | 6Q0 971 848 P | 6Q0 971 848 P qty: X || || X Bundling clip f wiring harness For hole/material thickness: use if required: | | Bundling clip f wiring harness For hole/material thickness: use if required: | 6X10/0, 6-2, 5 N 909 377.01 | X || || X | |
| | - | N10 732 501 | N10 732 501 qty: X corrugated pipe in coils of 5m'order unit 5' Temp. resistant: | | corrugated pipe in coils of 5m'order unit 5' Temp. resistant: | black -40C/+130C | X | |
| | - | 6R0 971 930 | 6R0 971 930 qty: X Bundling clip f wiring harness for bridge strength: Temp. resistant: | | Bundling clip f wiring harness for bridge strength: Temp. resistant: | 1-3MM -40C/+125C | X | |
| | - | N10 732 401 | N10 732 401 qty: X corrugated pipe in coils of 5m'order unit 5' Temp. resistant: | | corrugated pipe in coils of 5m'order unit 5' Temp. resistant: | black -40C/+130C | X | |
| | - | 5Q0 971 445 D | 5Q0 971 445 D qty: 1 Cable guidewater box | | Cable guidewater box | right | 1 | |
| | - | 5Q0 971 445 C | 5Q0 971 445 C qty: 1 Cable guidewater box | | Cable guidewater box | left | 1 | |
| | - | N10 732 401 | N10 732 401 qty: X corrugated pipe in coils of 5m'order unit 5' Temp. resistant: | | corrugated pipe in coils of 5m'order unit 5' Temp. resistant: | black -40C/+130C | X | |
| | - | 1E0 971 921 | 1E0 971 921 qty: 1 Bracket protective cover | | Bracket protective cover | | 1 | |
| | - | N10 732 601 | N10 732 601 qty: X corrugated pipe in coils of 5m'order unit 5' Temp. resistant: | | corrugated pipe in coils of 5m'order unit 5' Temp. resistant: | black -40C/+130C | X | |
| | - | N10 732 501 | N10 732 501 qty: X corrugated pipe in coils of 5m'order unit 5' Temp. resistant: | | corrugated pipe in coils of 5m'order unit 5' Temp. resistant: | black -40C/+130C | X | |
| | - | N10 732 401 | N10 732 401 qty: X corrugated pipe in coils of 5m'order unit 5' Temp. resistant: | | corrugated pipe in coils of 5m'order unit 5' Temp. resistant: | black -40C/+130C | X | |
| | - | 1J0 971 848 D | 1J0 971 848 D qty: X Cable clip | | Cable clip | | X | |
| | - | 5M0 971 838 | 5M0 971 838 qty: X cable tie with terminal socketWith side cable guide for bridge strength:Cable ties | | cable tie with terminal socketWith side cable guide for bridge strength:Cable ties | vertical Straight | X | |
| | - | 1Z0 971 904 | 1Z0 971 904 qty: X Bungs | | Bungs | | X | |
| | - | 5Q0 971 890 E | 5Q0 971 890 E qty: X bracket for connector housing | | bracket for connector housing | | X | |
| | - | 5Q0 971 856 | 5Q0 971 856 qty: X Retainer for control unit | | Retainer for control unit | lhd | X | |
| | - | 8S0 971 848 | 8S0 971 848 qty: X Cable holder D >> - 12.06.2020 | | Cable holder D >> - 12.06.2020 | | X | |
| | - | 5QD 971 848 A | 5QD 971 848 A qty: X Cable holder | | Cable holder | | X | |